Indoor Quality Analysis IAQ Monitoring Datalogger CO CO2 Delta Ohm HD37AB1347

Code: Delta Ohm HD37AB1347


 

Datasheet PDF, 0.41 Mb

Description

Datalogger for indoor air quality analysis (IAQ). The instrument measures the quantities: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide, only with P37AB147 probe). The SICRAM hotwire air speed probes, vane air speed probes, temperature probes, relative humidity and temperature combined probes can also be connected to the instrument. Memory capacity of 67,600 records for each of the two inputs. Logging interval from 15 seconds to 1 hour.

 

 

More products SENSECA

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DATALOGGER FOR PRESSURE, TEMPERATURE, FLOW RATE DELTA OHM DO9704

• Datalogger for pressure, flow rate and temperature measurements with 2 inputs,
• memory 512 Kbytes,
• storage of maximum, minimum and average value.
• RS232 C output

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

LABORATORY ELECTROCHEMICAL MULTIPARATEMER TESTER FOR DISSLVED OXIGEN, CONCENTRATION, SATURATION INDEX DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

THREE-CHANNEL VIBRATION ANALYZER FOR WORKERS PROTECTION DELTA OHM HD2070

• portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously
• measures all parameters required by current regulations concerning workers protection from vibration related risks
• measure vibrations transmitted to both hand-arm and whole body
• simplicity of use with maximum flexibility
• possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement
• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree