Multiplexer Module 40 channels Agilent 34921A

Code: Agilent 34921A


 

Datasheet PDF, 1.43 Mb

Description

  • 40 2-wire channels
  • 300V, 1A switch; 2A carry current
  • 100 ch/s scanning
  • Mix 2- or 4-wire configurations
  • 45 MHz Bandwidth
  • Built-in thermocouple reference junction
  • 4 current channels
  • Latching armature relays, with relay counter
 

More products KEYSIGHT

AGILENT 1604A HAND HELD DIGITAL OSCILLOSCOPE 2 X 40 MHZ

• 40 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter
• 11KS Maximum recording length viewable on screen with zoom function

 

PXI RF MATRIX SWITCH 3GHZ 1 X 16, 75 OHM AGILENT M9153A

• RF signal routing to 3 GHz for 75 ohm applications
• 1x16 75 ohm RF switch multiplexer to 3GHz
• 30V, 1A, 10W switching
• 75 ohm input impedance
• 56 dB isolation at 1 GHz

 

MULTIPLEXER MODULE 20 CHANNELS AGILENT 34901A

• 20 Channel Multiplexer
• Two- and four-wire scanning
• 300 V switching
• 60 ch/s scanning
• Built-in thermocouple reference junction

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 250KSA/S SIMULTANEOUS AGILENT U2541A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 250 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

AGILENT E4981A CAPACITANCE METER 120 HZ..1 MHZ

• 120 Hz, 1 kHz, 1 MHz measurement frequency
• 0.07% Basic accuracy
• High-speed measurements to 2.3 ms @ 1 MHz

 

GILENT 16822A PORTABLE LOGIC ANALYZER 68 CHANNELS & PATTERN GENERATOR 48 CHANNELS A

• 68-channel portable logic analyzer
• 48-channel pattern generator
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

PXI RF MATRIX SWITCH 3GHZ 1 X 8, 50 OHM AGILENT M9148A

• RF switching to 3 GHz
• 30V, 1A, 10W switching
• 42 dB isolation at 1 GHz
• 1.2 dB insertion loss at 3 GHz

 

USB MODULAR DATA ACQUISITION UNIT 16-CHANNELS 250KSA/S AGILENT U2352A

• High-speed USB 2.0
• 16-bit resolution
• 16 SE/8 DI multiplex analog input channels
• Up to 250 kSa/s sampling rate
• 24-bit programmable TTL input/output channels

 

AGILENT 16801A PORTABLE LOGIC ANALYZER 34 CHANNELS

• 34-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 250 MHz State clock rates
• up to 250 Mb/s Data rates
• up to 32 M acquisition memory depth

 

AGILENT 81180A ARBITRARY WAVEFORM GENERATOR 4.2 GSA/S

• 10-MS/s to 4.2-GSa/s sample clock control
• 2 GHz IQ modulation bandwidth
• 12 bit vertical resolution
• 1 or 2 channel, coupled or uncoupled