Agilent N9923A FieldFox Handheld Cable, Antenna, Vector Network Analyzer 2 MHz..4 GHz/ 6 GHz

Code: Agilent N9923A FieldFox Field-Fox


 

Datasheet PDF, 3.87 Mb

Description

  • Network Analyzer 2 MHz to 4 GHz/ 6 GHz
  • Transmission/reflection (S21, S11) or full two-port (S21, S11, S12, S22)
  • > 100 dB dynamic range
  • QuickCal, Enhanced response cal, and full 2-port cal
  • Cable and Antenna Analyzer 2 MHz to 4 GHz/ 6 GHz
  • Return loss, distance-to-fault, VSWR
  • Power Meter 9 kHz to 24 GHz, U2000 Series USB power sensor dependent
  • Vector Voltmeter 2 MHz to 4 GHz/ 6 GHz, compare phase and electrical length
  • Single and dual channel (A/B, B/A) measurements
 

Standard accessories

 

 

Recommended options

  • Option 104       4 GHz RF vector network analyzer, transmission/reflection
  • Option 106       6 GHz RF vector network analyzer, transmission/reflection
  • Option 112       QuickCal
  • Option 122       Full two-port S-parameters: S12, S22 and full two-port calibration
  • Option 302       External USB power sensor support
  • Option 305       Cable and antenna analyzer: DTF measurements
  • Option 308       Vector voltmeter
 

More products KEYSIGHT

AGILENT DSO6104L MODULAR OSCILLOSCOPE 4 X 1 GHZ

• 1 GHz bandwidth
• 4 scope channels (upgradeable to MSO with 16 digital channels)
• 4 GSa/s sample rate, 8 Mpts stand memory
• LXI class C compliant

 

SWITCH MODULE 64 CHANNELS AGILENT 34939A

• 64 Form A channels up to 1A, 50W
• Latching armature relays, with relay cycle counter
• Temperature sensor for overheating conditions

 

USB DATA ACQUISITION MAINFRAME CHASIS 3-SLOT AGILENT U2781A

• High-speed USB 2.0 (480 Mbit/s)
• Allows expansion up to 384 channels
• Hot-swappable and auto-detectable characteristic
• Internal and external 10 MHz reference clock

 

AGILENT 16806A PORTABLE LOGIC ANALYZER 204 CHANNELS

• 204-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

AGILENT 1604B HAND HELD DIGITAL OSCILLOSCOPE 2 X 40 MHZ

• 40 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter
• 125KS Maximum recording length viewable on screen with zoom function

 

DIGITAL OSCILLOSCOPE 2 X 500 MHZ AGILENT DSOX3052A

• 500 MHz bandwidth
• 2 analog channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


DIGITAL OSCILLOSCOPE 2 X 100 MHZ AND LOGIC ANALYZER 8 CHANNELS AGILENT MSOX2012A

• 100 MHz bandwidth
• 2 analog channels plus 8 digital channels
• 1GSa/s per channel sample rate

 

DIGITAL OSCILLOSCOPE 2 X 70 MHZ AGILENT DSOX2002A

• 70 MHz bandwidth
• 2 analog channels
• 1GSa/s per channel sample rate

 

DIGITAL OSCILLOSCOPE 4 X 100 MHZ AGILENT DSOX2014A

• 100 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

AGILENT 1602B HAND HELD DIGITAL OSCILLOSCOPE 2 X 20 MHZ

• 20 MHz bandwidth
• 2 analog channels
• 200MS/s sample rate
• 6000 count Digital Multimeter