Agilent E8257D PSG Microwave Analog Signal Generator 250 kHz..20 GHz/ 31.8 GHz/ 40 GHz/ 50 GHz/ 67 GHz

Code: Agilent E8257D PSG


 

Datasheet PDF, 3.64 Mb

Description

  • 250 kHz to 20 GHz, 31.8 GHz, 40 GHz, 50 GHz or 67 GHz operational to 70 GHz
  • 0.001 Hz resolution
  • +23 dBm @ 20 GHz, +17dBm @ 40 GHz, +14 dBm @ 67 GHz output power (typ); > +30 dBm (typ) with Option 521.
  • AM, FM, ØM, pulse, and scan
  • Extendable to 75, 90, 110, 140, 170, 220, 325, or 500 GHz - Millimeter-wave source modules
  • Industry’s best SSB phase noise Option UNY.
  • 8 ns rise/fall times and 20 ns pulse width (typ)
  • Dual internal function generators: sine, square, triangular, ramp, and noise
  • Step, list, and ramp sweep (frequency and power)
  • Source control using PSA Series Option 215
  • Agilent 8757D scalar network analyzer code compatible
  • 10BaseT LAN and GPIB
  • SCPI and IVI-COM drivers
  • Backwards compatible with all PSG signal generators
 

Recommended options

  • Option 520  250 kHz to 20 GHz
  • Option 521  10 MHz to 20 GHz
  • Option 532  250 kHz to 31.8 GHz
  • Option 540  250 kHz to 40 GHz
  • Option 550  250 kHz to 50 GHz
  • Option 567  250 kHz to 67 GHz  (operational up to 70 GHz)
 

More products KEYSIGHT

AGILENT 34405A DIGITAL PRECISION MULTIMETER 5.5 DIGIT

• 5.5 digit
• 0.025% DC voltage accuracy
• 120,000 counts resolution

 

AGILENT N9310A RF SIGNAL GENERATOR 9 KHZ..3 GHZ

• 9 kHz to 3 GHz
• 0.1 Hz resolution
• 20 Hz to 80 kHz low frequency (LF) output
• -127 to +13 dBm output level range (maximum +20 dBm settable)
• Optional IQ modulator, 40 MHz bandwidth

 

AGILENT 16802A PORTABLE LOGIC ANALYZER 68 CHANNELS

• 68-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

USB MODULAR DIGITAL I/O 32-CH. INPUT+32-CH. OUTPUT AGILENT U2651A

• Hi-Speed USB 2.0 (480 Mbps)
• 32 Input opto-isolated lines
• 32 Output opto-isolated lines
• Functions as standalone or modular unit
• Up to 1250 Vrms isolation protection

 

DIGITAL OSCILLOSCOPE 4 X 100 MHZ AGILENT DSO7014B

• 100 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

AGILENT E8267D PSG VECTOR SIGNAL GENERATOR 250 KHZ..20 GHZ/ 31.8 GHZ/ 44 GHZ

• 250 kHz to 20 GHz, 31.8 GHz or 44 GHz
• 0.001 Hz resolution
• +22 dBm @ 20 GHz and +18 dBm @ 40 GHz output power (typ)
• 160 MHz (extendable to 2 GHz) RF modulation bandwidth

 

AGILENT 4287A RF LCR METER 1 MHZ..3 GHZ

• 1 MHz to 3 GHz, with 100 kHz steps
• 1% basic accuracy
• Wide impedance measurement range from 200 milliohm to 3 kohm

 

AGILENT N5182A MXG VECTOR SIGNAL GENERATOR 100 KHZ..3 GHZ/ 6 GHZ

• 100 kHz to 3 GHz or 6 GHz
• 0.01 Hz resolution
• >+23 dBm up to 3 GHz using a highly-reliable, fast-switching electronic attenuator
• 100 MHz internal I/Q baseband generator
• Up to 64 MSa playback memory and 800 MSa storage

 

AGILENT N3300A N3301A N3302A N3303A N3304A N3305A N3306A N3307ADC ELECTRONIC LOADS

• 6 Slots - Full Rack Width Mainframe(N3300A Mainframe)
• 1800 Watts of Total Maximum Power(N3300A Mainframe)
• 2 Slots - Half Rack Width Mainframe(N3301A Mainframe)
• 600 Watts of Total Maximum Power(N3301A Mainframe)
• 
• 6 Modules available for configuring (150W to 600W)
• Max Voltage Input: 240V (N3303A)
• Max Current Input: 120A (N3306A)

 

DIGITAL OSCILLOSCOPE 4 X 350 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSO7034B

• 350 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog plus 16 digital channels
• Standard 8 Mpts MegaZoom III deep memory