Precision DC Current Source Keithley 6220

Code: Keithley 6220


 

Datasheet PDF, 0.36 Mb

Description

  • Source and sink (programmable load) 100fA to 100mA
  • 1014O output impedance ensures stable current sourcing into variable loads
  • 65000-point source memory allows executing comprehensive test current sweeps directly from the current source
  • Built-in RS-232, GPIB, Trigger Link, and digital I/O interfaces
  • Reconfigurable triax output simplifies matching the application's guarding requirements
  • Model 220 emulation mode eliminates need to reprogram existing applications
 

More products KEITHLEY

PCI BOARD 8-ANALOG OUTPUT KEITHLEY KPCI-3132

• 20mA output current without power supply
• 2 analog outputs

 

DIGITAL PRECISION MULTIMETER 7.5 DIGIT KEITHLEY DMM 2001

• 7.5 digit true resolution
• 8k Memory(optional 32k or 128k)
• Exceptional measurement integrity with high speed
• Broad range of built-in measurement functions

 

KEITHLEY 4200A-SCS I-V SEMICONDUCTOR CURVE TRACER PARAMETER ANALYZER

• Move C-V measurement to any device terminal without re-cabling
• User-configurable for low current capability
• Personalize the names of output channels
• View real-time test status

 

PRECISION AC AND DC CURRENT SOURCE KEITHLEY 6221

• Source and sink (programmable load) 100fA to 100mA
• 10^14 O output impedance ensures stable current sourcing into variable loads
• Source AC currents from 2pA to 100mA for AC characterization of components and materials

 

PICOAMMETER AND VOLTAGE SOURCE 5.5 DIGIT KEITHLEY 6487

• 10fA resolution
• 5-1/2 digit resolution
• <200µV burden voltage
• measure currents from 20fA to 20mA
• source voltage from 200µV to 505V

 

USB MODULAR DATA ACQUISITION UNIT USB 8-CHANNELS 50KSA/S KEITLHEY KUSB-3100

• USB 2.0 and USB 1.1, true plug-and-play compatibility
• 8 SE analog input channels
• 12-bit resolution
• Input/output speeds up to 50kS/s
• High and low programmable gains
• Up to 16 digital I/O lines

 

DIGITAL PRECISION MULTIMETER 8.5 DIGIT KEITHLEY DMM 2002

• 8.5 digit true resolution
• 8k Memory(optional 32k or 128k)
• Exceptional measurement integrity with high speed
• Broad range of built-in measurement functions

 

LOW CURRENT PHOTODIODE PICOAMMETER 2 CHANNLES KEITHLEY 2502

• Dual-channel instrument for optical power measurements, beam measurements, and nanoscale materials and device research
• ±100V source for bias requirements
• Measure photodetector current from 1fA to 20mA
• 1fA current measurement resolution

 

DATA ACQUISITION CARD PCI 32-CHANNELS 1.25MSA/S KEITLHEY KPCI-3110

• 12-bit resolution
• Maximum sampling rate of 1.25MS/s
• 32 single-ended or 16 differential analog inputs
• 2 analog outputs, waveform quality, up to 500kS/s
• 16 high speed digital I/O lines, up to 3MHz

 

HIGH VOLTAGE POWER SUPPLY 5 KV KEITHLEY 248

• Source voltages up to 5kV, negative or positive polarity
• Up to 5mA compliance current
• Low output ripple for precision sourcing