HIGHTEST TRAN-203 Transformer Analyzer for Turn Ration and Winding Resistance testing

Code: TRAN-203 TRAN203 TRAN-203B TRAN-203B


 

Datasheet PDF, 0.75 Mb
 

Description

TRAN-203 Three-Phase Transformer Analyser with Built-in Printer
TRAN-203B Three-Phase Transformer Analyser with Built-in Battery & Printer


The TRAN-203 series of instruments are designed to measure the turns ratio and winding resistance of three-phase and single-phase transformers. Via its user-friendly interface, the TRAN instrument/s provide a fast and accurate assessment of key transformer parameters.

TURNS RATIO MEASUREMENT

The TRAN-203 employs elements of performance tests specified in the ANSI/IEEE C57.12.90 standard. With market leading accuracy the TRAN-203 has a very wide ratio measurement capability with a precision of 0.08 %. Other features include the measurement of core excitation current, phase angle, polarity, ratio error and magnetic balance. Even though TRAN-203 has a three-phase cable configuration, users can also perform single-phase transformer tests.

TRAN-203 can detect vector groups automatically. The instrument has a wide operating range for use on equipment such as high excitation current transformers and high-power potential transformers in substations. The instrument can generate 1V, 4V, 10V, 40V, 100V, 250V AC test voltages.

WINDING RESISTANCE MEASUREMENT

Applying up to 20 Amps of direct current allows the TRAN -203 series to measure the resistance of three phase transformers primary and secondary windings automatically. TRAN-203 instrument/s are designed to measure the resistance of the primary and secondary transformer windings without the need to disconnect and reconnect the test cables.

Starting at 0.1 uOhm, the TRAN-203 series can measure up to 100,000 Ohm of resistance. The instrument can control OLTC. The TRAN-203 series can demagnetise the transformer to mitigate the build-up of remanence or residual magnetism due to the testing. Device discharges through its voltage channels in case High Voltage is present in the transformer under test.

The instrument also has a temperature measurement input which when connected to an optional temp sensor allows the TRAN-203 series to perform temperature correction or adjustments to its measurements. In the case of a failure in the current circuit the TRAN instrument/s intelligent software controls the flow of current to mitigate damage and provide added safety for users.

Heat run test/Temperature Rise Test

Heat run test or temperature rise test reproduces conditions of continuous rated load and the temperature rise occurring during the load. TRAN-203 is capable of measuring the winding resistance of transformers and the full load resistance Ro during heat run test by applying up to 20A DC.

An internal battery option is also offered for operators who feel that they may be in situations where a mains supply source isn�t always available. Multi-language capability and a user-friendly operating menu make it easy to control.

DEVICE HIGHLIGHTS

Turns Ratio & Winding Resistance Tests: TRAN has a 3-phase cable configuration cable of testing turns ratio and winding resistance of both three-phase and single-phase transformers.

Heat run test/ Temperature Rise Test: TRAN-203 is capable of measuring the full load resistance Ro during heat run test by applying up to 20A DC.

Optional Rechargeable Li-Ion Smart Battery: TRAN comes with a 14.4V Li-Ion smart battery option which enables you to make tests while on field. TRAN works on both main power and consuming battery power.

2.28-inch Built-in Thermal printer: TRANs built-in thermal printer let you print the results immediately during field test.

FEATURES

  • Turns ratio measurement (Single-phase & Three-phase)
  • Winding resistance measurement (Single-phase & Three-phase)
  • Heat run test/Temperature rise test
  • Magnetic Balance Test
  • 7-inch TFT Colour touch display
  • Built in 2.28-inch Printer
  • Battery & Bluetooth options
  • PC Software

TECHNICAL SPECIFICATIONS

Measurement Parameters3-Phase Turns Ratio Measurement, Excitation Current, Phase Angle, Polarity, Ratio Error (%), Vector group detection, Magnetic Balance; 3-Phase Winding Resistance Measurement
TURNS RATIO MEASUREMENT FEATURES
Ratio Measurement ModesCT Mode, PT Mode (Single-Phase and Three-Phase)
Measurement MethodANSI/IEEE C57.12
Test VoltagesCT Mode: 1 V and 4 V ; PT Mode: 1, 4, 10, 40, 100 & 250 V
Ratio Range0.8 - 50,000
Phase Angle Measurement0-360 Degree, ±0.2 degree
Excitation CurrentUp to 2 A
Excitation Current Accuracy ±0.1 mA
WINDING RESISTANCE MEASUREMENT FEATURES
Test Voltage50 V
Current outputFrom 0.001 A to 20 A DC (User-selectable)
Resolution5 digits
DemagnetisationYes

GENERAL FEATURES
Power Supply100-240 V, 47/63 Hz,
Battery14.4 V 6.9 Ah battery (Models: TRAN-203B, TRAN-203B BLUE)
Internal MemoryYes
Printer2.28-inch Built-in Printer
CommunicationUSB 2.0/1.1 Standard-A, USB 2.0/1.1 Standard-B, Bluetooth(Models: TRAN- 203BLUE & TRAN- 203B BLUE)
PC SoftwareData Management
 Platform Software
Display7-inch colour touch display
Dimensions  (429 x 328 x 236) mm
Weight9.5 kg
TemperatureWorking: -10 °C to +60 °C; Storage: -30 °C to +70 °C
Humidity95% RH Non-condensing
Protection ClassIP67 (case lid closed)

 

Standard accessories

Included in the packagePower Cable, Ground Cable, 2x 5m H&X Measurement Cable Set, 2x 10m H&X Extension Cable Set, 5m Tap Changer Cable Set, Jumper Cable, USB Cable, Printer Paper (x2), USB flash drive, Instruction Manual (Soft Copy), DMP Software, Cable Bag
 

More products HIGHTEST

HIGHTEST TRCAL-10K TURN RATIO METER CALIBRATOR

• Ratio Range 1 to 10,000 (1:1, 2:1, 5:1, 10:1, 50:1, 100:1, 200:1, 500:1, 1,000:1, 2,000:1, 5,000:1, 10,000:1)
• Exciting Voltage Range 1 V -250 V
• Exciting Windings H1-H2 Windings

 

HIGHTEST WINRES-20 WINDING RESISTANCE OHMMETER TESTER

• 2-channel resistance measurement
• Measurements from 0.1 uOhm to 100,000 Ohm
• 0.001 A to 20 A DC adjustable current output
• High accuracy (0.1%)
• Test Voltage 50 V
• Demagnetisation feature

 

HIGHTEST TRIORES-20 TRANSFORMER WINDING RESISTANCE TESTER

• Fully Automatic Three-phase and single-phase resistance measurement with three-phase cable configuration
• Measurement range, 0.1 uOhm to 100,000 Ohm
• 0.001 A to 20 A DC adjustable current output
• High accuracy (0.1%)
• Test Voltage 50 V
• Demagnetisation feature

 

HIGHTEST CIBRE-60 6-CONTACT TIMING CIRCUIT BREAKER ANALYSERS

• Contact Timing (O, C, O-C, C-O and O-C-O)
• Motion Tests (Transducer Speed, Stroke, Bounce)
• 6 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 7TFT Touch Colour Display

 

HIGHTEST TURA-03 TURN RATION TRANSFORMER TESTER TTR

• Turns Ratio Measurement (Single-phase and three-phase measurement)
• Ranges from 0.8 to 50,000 ratio measurement
• High Accuracy (0.08 %)
• 1V, 4V, 10V, 40V, 100V and 250V AC test voltages

 

HIGHTEST VABO-80 VACUUM BOTTLE TESTER FOR TESTING CIRCUIT-BREAKER VACUUM INTERRUPTER

• Circuit Breaker Vacuum Bottle Interrupter Testing
• Electrical Safety Gloves Integrity Test
• Automatic Testing
• 10 kV to 80 kV DC with 1 kV step voltages
• High Accuracy (1.5 %)
• 100 μA, 200 μA and 300 μA leakage current preset value

 

HIGHTEST PICU-1000 PRIMARY INJECTION CURENT SET 1000A

• High Current Capability Continuous output up to 1000A for primary injection applications.
• Multi-Purpose Testing Suitable for testing Protective Relays, MCCBs (Moulded Case Circuit Breakers), and CT Turns Ratio.
• Accurate & Reliable Provides precise measurement of current and operating time.
• Rugged & Portable

 

HIGHTEST CIBRE-30 CIRCUIT BREAKER TESTER ANALYZER

• Contact Timing (O, C, O-C, C-O and O-C-O)
• Motion Tests (Transducer Speed, Stroke, Bounce)
• 3 Dry Contact Inputs
• Timing Accuracy: 0.05% rdg ± 0.1 ms
• Timing Windows: 1s, 10s & 20s
• 2.28” Built-in Printer
• 7” TFT Touch Colour Display

 

HIGHTEST ARES-200D 200A LOW CONTACT RESISTANCE WITH DYNAMIC AND STATIC RESISTANCE MEASUREMENT

• ontact resistance measurement
• Adjustable current: 1 A to 200 A
• Measurement range from 0.1 µOhm to 5 Ohm
• Typical accuracy 0.1%
• Static resistance measurement
• Dynamic resistance measurement
• Dual ground test mode

 

HIGHTEST TURA-01 TRANSFORMER TURN RATIO TESTER

• Turns Ratio Measurement (Single-phase and three-phase measurement)
• Ranges from 0.8 to 33,000 Ratio Measurement
• High Accuracy (0.08 %)
• 1V, 4V, 10V, 40 V and 100 V AC Test Voltages