Brand: HART SCIENTIFIC

Thermocouple Furnace Calibrator 150°C..1200°C Hart Scientific 9150

Code: Hart Scientific 9150


 

Datasheet PDF, 0.1 Mb

Description

  • 150 °C to 1200 °C temperature range
  • Low-cost thermocouple furnace
  • NIST-traceable calibration included
  • RS-232 port standard
 

More products HART SCIENTIFIC

PRECISION REFERENCE 2-CHANNEL THERMOMETER HART SCIENTIFIC 1524

• Two channels
• High accuracy
• PRTs: up to ± 0.011 °C
• Thermocouples: up to ± 0.24 °C
• Precision thermistors: ± 0.002 °C
• memory for logging 15,000 measurements

 

SURFACE SENSOR CALIBRATOR 35°C..400°C HART SCIENTIFIC 3125

• Calibrates surface sensors up to 400°C
• Uses Hart 2200 Controller for excellent accuracy and stability
• NIST-traceable calibration included

 

INFRARED THERMOMETER CALIBRATOR 50°C..500°C HART SCIENTIFIC 9132

• Certify IR pyrometers from 50 °C to 500 °C
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design

 

INFRARED TEMPERATURE CALIBRATOR 50°C/ 100°C/ 150°C HART SCIENTIFIC 9135

• Fast and easy IR calibrations
• Three temperatures available: 50 °C, 100 °C, and 150 °C
• NIST-traceable calibration included

 

METROLOGY THERMOMETER CALIBRATION WELL 35°C..425°C HART SCIENTIFIC 9172

• 35 °C to 425 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

FLUKE HART SCIENTIFIC 1594A 1595A TEMPERATURE, THERMOMETER, THERMISTOR CALIBRATOR

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
• Accuracy as good as 0.06 ppm (0.000015 °C)
• "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL =10°C..122°C HART SCIENTIFIC 9102S

• -10°C to 122°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.05°C at 0°C

 

LOGGING THERMO-HYGROMETER HART SCIENTIFIC DEWK 1620A

• Superior accuracy
• NEW! Network enabled
• Powerful logging and analysis tools
• Two interchangeable calibrated sensors
• Huge memory

 

PRECISIN REFERENCE READOUT 4-CHANNEL THERMOMETER HART SCIENTIFIC 1529 CHUB-E4

• Four channels for PRTs, thermistors, and thermocouples
• Displays eight user-selected data fields from any channel
• Logs up to 8,000 readings with date and time stamps
• Battery provides eight hours of continuous operation

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL 35°C..375°C HART SCIENTIFIC 9100S

• 35°C to 375°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.07°C at 0°C