Brand: HART SCIENTIFIC

Surface Sensor Calibrator 35°C..400°C Hart Scientific 3125

Code: Hart Scientific 3125


 

Datasheet PDF, 0.09 Mb

Description

  • Calibrates surface sensors up to 400°C
  • Uses Hart 2200 Controller for excellent accuracy and stability
  • NIST-traceable calibration included
 

More products HART SCIENTIFIC

FIELD METROLOGY TEMPERATURE CALIBRATION WELL 33°C..350°C HART SCIENTIFIC 9143

• 33 °C to 350 °C (91 °F to 662 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.02 °C

 

FIELD METROLOGY TEMPERATURE CALIBRATION WELL 50°C..660°C HART SCIENTIFIC 9144

• 50 °C to 660 °C (122 °F to 1220 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Heat to 660 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.03 °C

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL 35°C..375°C HART SCIENTIFIC 9100S

• 35°C to 375°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.07°C at 0°C

 

THERMOCOUPLE FURNACE CALIBRATOR 150°C..1200°C HART SCIENTIFIC 9150

• 150 °C to 1200 °C temperature range
• Low-cost thermocouple furnace
• NIST-traceable calibration included
• RS-232 port standard

 

INFRARED THERMOMETER CALIBRATOR -30°C..150°C HART SCIENTIFIC 9133

• Certify IR pyrometers from -30 °C to 150 °C
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 35°C..350°C HART SCIENTIFIC 9140

• 35 °C to 350 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.03 °C stability

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL =10°C..122°C HART SCIENTIFIC 9102S

• -10°C to 122°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.05°C at 0°C

 

THERMOCOUPLE FURNACE CALIBRATOR 300°C..1100°C HART SCIENTIFIC 9112B

• 300 °C to 1100 °C temperature range
• Combined stability and uniformity better than ±0.4°C
• RS-232 serial interface standard
• High capacity for simultaneous comparison calibrations

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 50°C..650°C HART SCIENTIFIC 9141

• 50 °C to 650 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.05 °C stability

 

TEMPERATURE CALIBRATION OIL MICRO-BATH -30°C..125°C HART SCIENTIFIC 7103

• -30 °C to 125 °C range
• World’s smallest portable calibration baths
• Calibrates sensors of any size or shape
• Stability to ±0.03°C