Brand: HART SCIENTIFIC

Dual Industrial Temperature Calibration Block -15°C..350°C Hart Scientific 9009

Code: Hart Scientific 9009


 

Datasheet PDF, 0.12 Mb

Description

  • Temperatures from -15 °C to 350 °C in one unit
  • 50 °C to 350 °C Hot block, ± 0.6 °C Accuracy
  • -15 °C to 110 °C Cold Block,  ± 0.2 °C Accuracy
  •  ± 0.05 °C Stability
  • Two wells in each block for simultaneous comparison calibrations
  • Rugged, lightweight, water-resistant enclosure
 

Recommended options

9009-X 

Industrial Dual-Block Dry-Well (X = case color. Specify "B" for black or "Y" for yellow.)  Includes two 1/4 in (6.4 mm) and two 3/16 in (4.8 mm) inserts. 

SC1-FDDW

Extended Warranty, Silver Care, Field Dry-well

3102-0 

Insert, Blank 

3102-1 

Insert, 1/16 in (1.6 mm) 

3102-2 

Insert, 1/8 in (3.2 mm) 

3102-3 

Insert, 3/16 in (4.8 mm) 

3102-4 

Insert, 1/4 in (6.4 mm) 

3102-5 

Insert, 5/16 in (7.9 mm) 

3102-6 

Insert, 3/8 in (9.5 mm) 

3102-7 

Insert, 7/16 in (11.1 mm) 

3102-8 

Insert, 5/32 in (4 mm) 

 

More products HART SCIENTIFIC

REFERENCE TWEENER THERMOMETER HART SCIENTIFIC 1502A / 1504

• Two Tweeners to choose: reading PRTs(1502A) or thermistors(1504)
• Battery packs available
• Best price/performance package

 

TEMPERATURE CALIBRATION HANDHELD DRY WELL 35°C..375°C HART SCIENTIFIC 9100S

• 35°C to 375°C range
• Smallest dry-wells in the world
• Accuracy to ±0.25°C
• stability of ±0.07°C at 0°C

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 50°C..650°C HART SCIENTIFIC 9141

• 50 °C to 650 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.05 °C stability

 

DUAL INDUSTRIAL TEMPERATURE CALIBRATION BLOCK -15°C..350°C HART SCIENTIFIC 9009

• Temperatures from -15 °C to 350 °C in one unit
• 50 °C to 350 °C Hot block, ± 0.6 °C Accuracy
• -15 °C to 110 °C Cold Block, ± 0.2 °C Accuracy
• ± 0.05 °C Stability

 

FLUKE HART SCIENTIFIC 1594A 1595A TEMPERATURE, THERMOMETER, THERMISTOR CALIBRATOR

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
• Accuracy as good as 0.06 ppm (0.000015 °C)
• "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors

 

THERMOCOUPLE FURNACE CALIBRATOR 300°C..1100°C HART SCIENTIFIC 9112B

• 300 °C to 1100 °C temperature range
• Combined stability and uniformity better than ±0.4°C
• RS-232 serial interface standard
• High capacity for simultaneous comparison calibrations

 

METROLOGY THERMOMETER CALIBRATION WELL 50°C..700°C HART SCIENTIFIC 9173

• 50 °C to 700 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

METROLOGY THERMOMETER CALIBRATION WELL 35°C..425°C HART SCIENTIFIC 9172

• 35 °C to 425 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 35°C..350°C HART SCIENTIFIC 9140

• 35 °C to 350 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.03 °C stability

 

FIELD METROLOGY TEMPERATURE CALIBRATION WELL -25°C..150°C HART SCIENTIFIC 9142

• -25 °C to 150 °C (-13 °F to 302 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Cool to -25 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.01 °C