This device supports all above mentioned "common advantages". It is especially popular among medics and alternative practitioners, as it offers a perfect combination of easy handling and professional measurement possibilities. It allows an easy allocation of the electrosmog frequencies to the traction power or the mains power as well as to the artificial harmonics, thus facilitating an especially precise consultation of remedial actions and an easy control of their effectiveness.

Frequency range: 5 Hz - 100 KHz (compensated, better than -2 dB).

 

Features:

  • The reading shows the total pollution without any calculation required.
  • The measured values are reliably displayed directly in the entity corresponding to the building biology standard values, namely:
  • The electric field strength from 1 to 1999 V/m (against ground potential)
  • The magnetic flux density from 1 to 1999 nT.
  • An acoustic signal proportional to the field strength with "Geiger-counter-effect" helps identifying regions with increased exposure.
  • A switchable internal filter module as in the professional devices, allowing a numeric differentiation of traction power and mains supply as well as the artificial higher frequencies. A useful aspect considering the even lower precautionary values for higher frequencies.

 

 

More products GIGAHERTZ

GIGAHERTZ SOLUTIONS - LOW FREQUENCY ANALYSER ME3830B

• A clearly extended frequency range: from 16 Hertz to 100 Kilohertz. This frequency range (in accordance with SBM) also includes the higher frequencies caused by, for instance, energy saving lamps, switching-mode power supplies, electronic dimmers, or monitors, which are considered especially critical.

 

GIGAHERTZ SOLUTIONS - HF-ANALYSER HF32D

• The reading shows the total pollution without any calculation required.
• The measured values are reliably displayed directly in the entity corresponding to the building biology standard values.
• An acoustic signal proportional to the field strength with "Geiger-counter-effect" helps identifying regions with increased exposure.
• Digital display of 1 µW/m² up to 1999 µW/m².

 

GIGAHERTZ SOLUTIONS - HF-ANALYSER HF38B

• A 10 times higher sensitivity: Minimum display resolution 0.01 µW/m² .
• A measuring range extended upwards by a factor of 10: max. 19.99 mW/m² .
• Clearly simplified measurements with the help of the "peak-hold"- function.

 

GIGAHERTZ SOLUTIONS - HF-ANALYSER HFW59D

• Includes an especially shielded log-per antenna with excellent directional characteristics.
• Integrated steep high pass filter at 2.4 GHz reliably suppresses the often dominant GSM and DECT frequencies.
• Calibrated AC measurement output for the demodulated signal, scalable DC output.

 

GIGAHERTZ SOLUTIONS - LOW FREQUENCY ANALYSER ME3951A

• Responsivity increased by a factor of 10 (minimum display resolution: 0.1 V/m / 0.1 nT).
• NiMH battery, battery charger / power supply unit included.
• An AC- and a DC-output.

 

GIGAHERTZ SOLUTIONS - LOW FREQUENCY ANALYSER ME3851A

• NiMH battery, battery charger / power supply unit included.
• An AC- and a DC-output.
• Increased reliability by the use of a test switching mode for the zero deviation.

 

GIGAHERTZ SOLUTIONS - HF-ANALYSER SET HFW59D PLUS

• Maximum video band width for the demonstration of the shortest radar pulses (< 0.5 µs).
• Optimized Peak Hold function (patent no. DE 103 34 886).
• HV20_2400G10 included for maximum sensitivity within the full frequency range: 0.01 mW/m² display resolution for measurements of weakest WLAN signals.
• Includes an especially shielded log-per antenna with excellent directional characteristics.

 

GIGAHERTZ SOLUTIONS - 3D-LF-ANALYSER WITH DATA LOGGER NFA400

• ONE-dimensional potential-free measurement of the electric field (Y-axis).
• Non-isolated electric field measurement possible with integrated sensor or with the optionally available TCO conform probe TCO3.
• An integrated voice recorder facilitates the measruement analysis.

 

GIGAHERTZ SOLUTIONS - HF-ANALYSER HF59B

• A frequency range of down to 27 MHz within the basic device - suitable for the connection of the optionally available antenna UBB27_G3 (the scope of delivery includes a compensated antenna for 800 MHz up to 2.7 or 3.3 GHz).
• A calibrated extra AC-measurement output for the demodulated signal, and a scalable DC-output.
• HINT: If you only need to measure above 800 MHz the HF58B-r is the cheaper and better solution for you. Only with the antenna UBB27 (included in the kit HFE59B) you can in fact measure frequencies below 800 MHz (e.g. digital TV, TETRA, new GSM Channels in Europe).

 

GIGAHERTZ SOLUTIONS - 3D-LF-ANALYSER WITH DATA LOGGER NFA1000

• Non-isolated electric field measurement possible with integrated sensor or with the optionally available TCO conform probe TCO3.
• An integrated voice recorder facilitates the measurement analysis.
• Please have a look at the data sheet (to be found under "available downloads") for detailed descriptions of the broad performance range of this meter, also in comparison to the other NFAs.