True-rms Current Clamp Meter 400 A Fluke 325

Code: Fluke 325


 

Datasheet PDF, 0.9 Mb

Description

Measurement capability

  • 400 A ac and dc current measurement
  • 600 V ac and dc voltage measurement
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 40 k? with continuity detection
  • Temperature and capacitance measurement
  • Frequency measurement


Features

  • Slim, ergonomic design
  • Large, easy to read backlight display
  • CAT IV 300V/CAT III 600 V safety rating
  • Hold button
  • Two-year warranty
  • Soft carrying case
 

Standard accessories

  • Test leads
  • Soft case
  • User's manual
 

Recommended options

 

 

More products FLUKE

FLUKE 43B POWER QUALITY ANALYZER

• Power Quality Analyzer Measures power (W, VA, VAR) and power factor (PF, DPF)
• Oscilloscope Dual-channel scope 20 MHz bandwidth
• Multimeter
• Recorder
• Harmonics Up to 51st
• Power One and three phase

 

FLUKE 714B THERMOCOUPLE CALIBRATOR

• measure and simulate (17) different thermocouple types and millivolts
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

FLUKE 289 HANDHELD DIGITAL DATA LOGGING MULTIMETER 4.5 DIGIT

• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture
• Low input impedance function (LoZ)
• Motor winding and low ohm measurement range
• Low pass filter

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 743B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging

 

DOCUMENTING PROCESS CALIBRATOR FLUKE 744

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate
• PC interface and data logging
• Integrated HART communication

 

WIRELESS AC VOLTAGE MODULE FLUKE CNX V3000

• True-RMS AC voltage measurements to 1000V
• ±1% accuracy to 500 Hz, ± 2% accuracy to 1 kHz
• Memory recording up to 65,000 readings
• Backlit LCD display
• CAT IV 600 V, CAT III 1000 V; IP42


FLUKE MEMOBOX 1745 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• five hour UPS
• IP50 advanced protection

 

FLUKE 190-502 190-502/S HANDHELD DIGITAL OSCILLOSCOPE 2X500 MHZ

• 2-channels isolated 500MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

FLUKE 190-062 190-062/S HANDHELD DIGITAL OSCILLOSCOPE 2X60 MHZ

• 2-channels isolated 60MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity

 

HANDHELD VOLT/MA CALIBRATOR FLUKE 715

• 0 to 200 mV, 0 to 20 V Voltage measure
• 0 to 100mV, 0 to 10 V Voltage source / simulate
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• very high accuracy of 0.015% and 1 mA resolution