Handheld Volt/mA Calibrator Fluke 715

Code: Fluke 715


 

Datasheet PDF, 0.53 Mb

Description

  • 0 to 200 mV, 0 to 20 V Voltage measure
  • 0 to 100mV, 0 to 10 V Voltage source / simulate
  • 0 to 24 mA Current measure
  • 0 to 20 mA Current source / simulate
  • Measure loop current (0-20 mA, 4-20 mA) signals with very high accuracy of 0.015% and 1 mA resolution
  • Measure voltage output process signals from PLCs, transmitters
  • 24V loop supply with simultaneous current measurement
  • Enhanced voltage and current measure and source accuracy
  • Improved battery life
  • 250 ohm HART resistor with loop power
  • Holster features test lead storage
  • Compatible with toolpack magnetic hanging system
  • Step and linear ramp output function
  • Configurable zero and span settings
 

Standard accessories

  • Protective Yellow Holster with Test Lead Storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST- traceable calibration report and data
 

More products FLUKE

MILIAMP PROCESS CLAMP METER FLUKE 773

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity
• 0 to 30 V DC Voltage measure
• 0 to 10 V DC Voltage source

 

FLUKE TI400 INFRARED CAMERA 320X240 RESOLUTION

• 320x240 Detector resolution
• Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation
• Range: -20 °C si +1200 °C
• Precision : ± 2 °C sau 2%
• Sensibility : = 0,05 °C

 

HANDHELD LOOP CALIBRATOR FLUKE 705

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.02%

 

FLUKE 1652C MULTIFUNCTION INSTALLATION TESTER 250V-1000V

• Test voltage: 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results

 

CURRENT CLAMP METER TRUE-RMS AC/DC FLUKE 381

• Detachable digital display, read measurements up to 30 feet away
• iFlex fexible current probe included, 18-inch circumference
• 2500 A AC current measurement with iFlex
• 1000 A AC current measurement with fxed jaw
• 1000 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60-k O resistance measurement
• 500 mV DC measurement range
• 1000 µF capacitance measurement

 

FLUKE 719PRO ELECTRIC PRESSURE CALIBRATOR

• Fluke-719Pro-30G -12 to 30 PSI / -0.8 to 2 bar
• Fluke-719Pro-150G -12 to 150 PSI / -0.8 to 10 bar
• Fluke-719Pro-300G -12 to 300 PSI / -0.8 to 20 bar
• Unique integrated electric pump for one handed pressure calibration
• Pressure measurement from internal or external sensor
• Sourced/simulated or measured mA values
• Temperature measured by optional RTD probe

 

AC VOLTAGE DATA ACQUISITION RECORDING KIT FLUKE FLK-CNX V3000 KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC voltage measurements to 1000V
• Memory recording up to 65,000 readings
• CAT III 1000 V; CAT IV 600 V; IP42


WIRELESS AC CURRENT MEASUREMENT KIT FLK-CNX I3000 IFLEX KIT

• True-RMS AC and DC voltage measurements to 1000V
• True-RMS AC and DC current with 0.01 mA resolution
• True-RMS AC current measurements to 2500 A
• Memory recording up to 65,000 readings
• CAT III 1000, CAT IV 600 V; IP42


FLUKE TIS40 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

FLUKE 700HTPK HYDRAULICTEST KIT FOR PRESSURE CALIBRATION

• Combine with any Fluke-700G Series Gauge, 1,000 psi range or greater, to make a complete pressure testing kit
• Generates pressure up to 10,000 psi range or greater, to make a complete pressure testing kit
• Connect the 700G Series gauge directly to the HTP-2 hand pump
• Includes 700HTH-1 hose kit and adapters for connecting to the pressure device to be tested
• Hard case protects pump and gauge and allows gauge to remain connected to the pump