Fluke 116 Handheld Digital Multimeter HVAC 3.5 digit

Code: Fluke 116


 

Datasheet PDF, 0.13 Mb

Description

  • 3.5 digit
  • 6000 count
  • 0.5% accuracy
  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak™)
  • CAT III 600 V safety rated
 

Standard accessories

  • Test leads with 4 mm lantern tips and
  • protective cap
  • holster
  • installed 9V battery
  • users manual
 

More products FLUKE

FLUKE 712B RTD TEMPERATURE CALIBRATOR

• measure and simulate (13) different RTD types and resistance
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

DOCUMENTING PROCESS CALIBRATOR-HART FLUKE 753

• Measure volts, mA, RTDs, thermocouples, frequency
• ohms to test sensors, transmitters and other instruments
• Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure
• Power transmitters during test using loop supply with simultaneous mA measurement
• HART Capabilities

 

ELECTRIC PRESSURE CALIBRATOR FLUKE 719

• Best in class pressure measurement uncertainty of 0.025%
• Measure and source mA with best in class 0.015% accuracy
• 30 PSI and 100 PSI pressure ranges

 

FLUKE 1654B MULTIFUNCTION INSTALLATION TESTER 50V-1000V

• Test voltage: 50V, 100V, 250V, 500V, 1000V
• Two measurements at once and a dual display
• PEFC/PSC and loop impedance
• Fast voltage measurement between L-N, L-PE and N-PE
• PASS/FAIL indication for RCD test results
• Earth resistance

 

FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

PRESSURE CALIBRATOR FLUKE 718

• Pressure Source and Milliamp Measurement
• Best in class mA accuracy of 0.015 %
• 1, 30, 100 & 300 PSI ranges available

 

INTRINSICALLY SAFE CALIBRATOR FLUKE 725EX

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 10 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 3200 O Resistance measure / source / simulate
• 1 to 10 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure
• ATEX II 1 G Ex ia IIB 171°C KEMA 04ATEX 1303X

 

FLUKE TIS40 INFRARED CAMERA 160X120

• Fluke TiS10 80x60 pixels
• Fluke TiS20 120x90 pixels
• Fluke TiS40 160x120 pixels
• Fluke TiS45 160x120 pixels
• Fluke TiS50 220x165 pixels
• Fluke TiS55 220x165 pixels
• Fluke TiS60 260x195 pixels
• Fluke TiS65 260x195 pixels

 

HANDHELD VOLT/MA CALIBRATOR FLUKE 715

• 0 to 200 mV, 0 to 20 V Voltage measure
• 0 to 100mV, 0 to 10 V Voltage source / simulate
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• very high accuracy of 0.015% and 1 mA resolution

 

HVAC CURRENT CLAMP METER 600 A FLUKE 902

• Designed for HVAC applications
• capacitance, DC Current (µA), and temperature measurements
• Small body and jaws