Extech PQ3350-3 3-Phase Power & Harmonics Analyzer

Code: Extech PQ3350-3


 

Datasheet PDF, 0.37 Mb

Description

Complete with 3000A 24" flexible current clamp probes

Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

 

Features:

  • Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings)
  • Flexible clamp probes can be used for wrapping around bus bars and wire bundles
  • Large backlighting LCD displays up to 35 parameters in one screen
  • Clamp-on True RMS power measurements with on-screen Harmonics display
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 3000) and VT ratio (1 to 600)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics
  • Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case
 

More products EXTECH

EXTECH PRC10: CURRENT CALIBRATOR/METER

• 0 to 24mA (-25 to 125%) readout
• 24V DC power source for 2-wire current loop
• Up to five user adjustable calibration presets
• Palm-sized double molded housing and large dot-matrix digital backlit LCD
• Standard banana I/O ports
• Large battery bank for extended work cycle

 

EXTECH 380580 BATTERY POWERED MILLIOHM METER

• Four terminal Kelvin measurements
• Over-temperature and over-voltage protection
• 5 ranges with 100µOhm max resolution
• Invalid test indicators prevent inaccurate measurements
• Built-in water resistant case with shoulder strap

 

EXTECH 475040-SD FORCE GAUGE DYNAMOMETER WITH DATALOGGING

• Features 5000g, 176 oz. and 49 Newtons measurement capacity
• Large dual backlit LCD with reversible display feature to match viewing angle
• Record data on SD card
• Updates reading every 0.2 seconds and sample rate is 1 second to 9 hours
• Integrated load cell measurement transducer

 

EXTECH MO57 PINLESS MOISTURE METER

• Pinless moisture measurement depth to <4" (100mm)
• Measures Moisture up to 99.9% for Wood and other building materials
• Displays moisture level in wood and building materials such as wall board, sheet rock, tiles, cardboard, plaster, concrete, and mortar
• Audible Alert - Tone rate beeps faster as the moisture level increases
• Icons display low, medium and high levels of moisture content

 

EXTECH MN16A DIGITAL MINI MULTIMETER

• Large easy to read digital display
• AC/DC Voltage & Current, Resistance, Capacitance, Frequency, Continuity, Diode Test, Type K Temperature and Duty Cycle
• Auto power off with disable feature
• Complete with two AAA batteries, general purpose Type K bead wire probe and test leads

 

EXTECH MA620 600A TRUE RMS AC CLAMP METER + NCV

• AC Current, AC/DC Voltage, Resistance, Frequency, Capacitance, Temperature, Duty Cycle, Diode and Continuity
• Integrated Non-Contact Voltage Detector with LED alert
• 1.5" (40mm) jaw size for conductors up to 500MCM
• 6000 count, backlit LCD display

 

EXTECH RHT50 HUMIDITY/TEMPERATURE/PRESSURE DATALOGGER

• Datalogs up to 10,000 readings with a user programmable sample rate
• USB interface for easy set-up and data download
• Selectable Atmospheric Pressure Units: psi, hPa, kPa, and bar
• Selectable data sampling rate from 1 minute to 18 hours

 

EXTECH MO257 PINLESS MOISTURE METER

• Non-invasive moisture content measurements in wood/building materials
• Measures relative moisture of various building materials including wood, particle board, carpeting, and ceiling tiles using non-invasive Pinless Technology
• Multifunction backlit triple LCD display
• Pinless measurement depth from 0.78" (20mm) to 1.6" (40mm) below the surface
• High frequency sensing technology

 

EXTECH MN35 DIGITAL MINI MULTIMETER

• Large easy to read digital display
• AC/DC Voltage, DC Current, Resistance, Type K Temperature, Continuity/Diode
• 1.5V and 9V Battery test function
• Convenient mini size with protective rubber holster and tilt stand
• Data Hold locks reading in the display
• Includes protective rubber holster, 9V battery, bead wire Type K temp. probe and test leads

 

EXTECH 407732: LOW/HIGH RANGE SOUND LEVEL METER

• High accuracy meets ANSI and IEC 651 Type 2 standards
• High and Low measuring ranges: 35 to 100dB (low) and 65 to 130dB (high)
• Data Hold and Max Hold functions
• Backlit LCD display to view in dimly lit area