Extech PQ3350-3 3-Phase Power & Harmonics Analyzer

Code: Extech PQ3350-3


 

Datasheet PDF, 0.37 Mb

Description

Complete with 3000A 24" flexible current clamp probes

Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

 

Features:

  • Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings)
  • Flexible clamp probes can be used for wrapping around bus bars and wire bundles
  • Large backlighting LCD displays up to 35 parameters in one screen
  • Clamp-on True RMS power measurements with on-screen Harmonics display
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 3000) and VT ratio (1 to 600)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics
  • Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case
 

More products EXTECH

EXTECH MG500 DIGITAL HIGH VOLTAGE INSULATION TESTER 10KV

• High test voltages up to 10kV with Insulation Resistance to 500GOhm
• Polarization Index (PI) measurement
• Dielectric Absorption Ratio (DAR) measurement
• EnerSave™ limits test duration to 10 seconds to save energy
• Complete with built-in heavy duty carrying case with cover, test leads, alligator clips, and 8 x C batteries

 

EXTECH GX900 TRUE RMS GRAPHICAL MULTIMETER WITH BLUETOOTH®

• Integrated Bluetooth® connects with most Android devices to transmit readings for remote viewing
• Works with free Android App to display large, easy-to-read values up to 30ft (10m) away
• Low Pass Filter conditions the inputs to provide accurate Voltage and Frequency readings on motors, drives and other large electrical equipment that generate electrical noise
• Datalogging stores up to 2500 readings with date and time stamp

 

EXTECH 380260 AUTORANGING DIGITAL MEGOHMMETER

• 250V, 500V, and 1000V test voltages
• Insulation Resistance to 2000MOhm
• Lo Ohm function for testing connections
• Lock Power On Function for hands-free operation

 

EXTECH ET10: GFCI RECEPTACLE TESTER

• Works with GFCI circuits
• Tests for faulty wiring in 3-wire receptacles: Correct, Open Ground, Open Neutral, Open Hot, Hot/Ground Reverse, Hot/Neutral Reverse
• Lights indicate circuit condition
• Standard North American 3-prong plug

 

EXTECH HD700 DIFFERENTIAL PRESSURE MANOMETER (2PSI)

• ±2psi range, 11 Selectable units of measure
• Max/Min/Avg recording and Relative time stamp
• Data Hold, Auto power off and Zero function
• Large LCD display with backlighting

 

EXTECH MA150 200A MINI AC CLAMP METER + NCV DETECTOR

• 0.7" (18mm) jaw opening
• 2000 count backlit LCD display
• Non-contact AC Voltage detector (100 to 600VAC) via clamp tip
• Built-in white LED flashlight
• Continuity and Diode Test, Max Hold, Auto power off

 

EXTECH CO15: CARBON MONOXIDE (CO) METER

• Dual LCD simultaneously displays Carbon Monoxide (CO) level and maximum CO reading taken from when the meter was powered on
• Long life electrochemical sensor
• Adjustable CO warning level at 25, 30, 35, 45, 50, 70, 100 and 200ppm (alarm is preset to 25ppm)
• Audible alarm when CO level reaches the warning set point level
• Choose from 3 calibration points: 0 (preset), 100, and 500ppm

 

EXTECH 380360 DIGITAL MEGOHMMETER

• Three test voltages of 250V, 500V and 1000V
• Insulation Resistance to 2000MOhm
• Safety Power Lock enables "hands free" operation for 3 minute test
• Automatic discharge when safety "Press to Test" button is released
• Continuity measurements to 200Ohm and Voltage to 600VAC

 

EXTECH MO50 MOISTURE METER

• Displays moisture level in wood and building materials such as wall board, sheet rock, cardboard, plaster, concrete, and mortar
• Audible Alert - tone rate beeps faster as the moisture level increases
• Icons display low, medium and high levels of moisture content
• Easy-to-use, compact-sized design

 

EXTECH 480823 SINGLE AXIS EMF/ELF METER

• Measure electromagnetic field radiation levels from fans, electrical appliances, wiring, and power lines
• Large 1/2" LCD (1999 count) display of Electromagnetic Field (EMF) level in milliGauss or microTesla
• Accurate measurements to 4% over a measuring range of 0.1 to 199.9mGauss (0.01 to 19.99µTesla)
• ELF frequency bandwidth of 30Hz to 300Hz
• Single axis - sampling 2.5 times per second