Extech PQ3350-3 3-Phase Power & Harmonics Analyzer

Code: Extech PQ3350-3


 

Datasheet PDF, 0.37 Mb

Description

Complete with 3000A 24" flexible current clamp probes

Complete with 3000A 18" flexible current clamp probes. Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings). Flexible clamp probes can be used for wrapping around bus bars and wire bundles. Large backlighting LCD displays up to 35 parameters in one screen. Clamp-on True RMS power measurements with on-screen Harmonics display. Simultaneous display of Harmonics and Waveform. Display of Waveform with Peak Values (1024 samples/period). Analysis of Total Harmonic Distortion (THD-F). Maximum Demand (MDkW, MW, kVA, MVA) with programmable period. Adjustable CT ratio (1 to 600) and VT ratio (1 to 3000). Graphic Phase diagram with 3-Phase system parameters. 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%). Calculated Unbalanced Current through Neutral Line (In). Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%). Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics. Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case.

 

Features:

  • Datalogging of single and 3-phase/3-wire or 3-phase/4-wire systems (up to 52,428 single phase readings or 17,476 3-phase readings)
  • Flexible clamp probes can be used for wrapping around bus bars and wire bundles
  • Large backlighting LCD displays up to 35 parameters in one screen
  • Clamp-on True RMS power measurements with on-screen Harmonics display
  • Simultaneous display of Harmonics and Waveform
  • Display of Waveform with Peak Values (1024 samples/period)
  • Analysis of Total Harmonic Distortion (THD-F)
  • Maximum Demand (MDkW, MW, kVA, MVA) with programmable period
  • Adjustable CT ratio (1 to 3000) and VT ratio (1 to 600)
  • Graphic Phase diagram with 3-Phase system parameters
  • 3-phase Voltage or Current Unbalanced Ratio (VUR, VIR) and Unbalanced Factor (d0%, d2%)
  • Calculated Unbalanced Current through Neutral Line (In)
  • Capture 28 Transient events (including Dip, Swell and Outage) with programmable threshold (%)
  • Optically isolated USB interface with software to download Waveforms, Power Parameters and Harmonics
  • Includes 3 flexible current clamps, 4 voltage leads with alligator clips and retractable plunger clips, 8 AA batteries, universal AC adaptor, software, USB interface cable, and case
 

More products EXTECH

EXTECH EN100 11-IN-1 ENVIRONMENTAL METER

• Built-in sensors measure Air Velocity, Air Flow, Temperature, Humidity, Wet Bulb, Dew Point, Heat Index, Wind Chill, Barometric Pressure, Altitude, and Light
• Field replaceable low friction vane wheel improves air velocity accuracy
• Backlit LCD display (auto off after 5 seconds)
• Data Hold, Auto Power Off, Auto-rotating display depending on function
• Complete with built-in multiparameter sensors, wrist strap, and CR2032 battery

 

EXTECH EX810 1000A AC CLAMP METER WITH IR THERMOMETER

• Non-contact InfraRed Temperature measurements with laser pointer
• Peak hold captures inrush currents and Transients
• MultiMeter functions include AC/DC Voltage, AC Current, Resistance, Capacitance, Frequency, Diode, and Continuity
• 1.7" (43mm) jaw opening for conductors up to 750MCM or two 500MCM
• 4000 count backlit display
• Autoranging with manual range button

 

EXTECH PRC15: CURRENT AND VOLTAGE CALIBRATOR/METER

• 0 to 24mA (-25 to 125%) readout
• 0 to 20V DC calibration source
• Up to five user adjustable calibration presets
• Palm-sized double molded housing and large dot-matrix digital backlit LCD
• Standard banana I/O ports

 

EXTECH 475040 FORCE GAUGE DYNAMOMETER

• Range: 176 oz, 5000g, 49 Newtons (±0.4% accuracy)
• Ideal for a wide variety of applications in the electronics, automotive, chemical, plastics and machinery industries
• Reversible display and fast/slow response mode
• Exclusive load cell measurement transducer
• Overrange, low battery and advanced function indication

 

EXTECH MO50 MOISTURE METER

• Displays moisture level in wood and building materials such as wall board, sheet rock, cardboard, plaster, concrete, and mortar
• Audible Alert - tone rate beeps faster as the moisture level increases
• Icons display low, medium and high levels of moisture content
• Easy-to-use, compact-sized design

 

EXTECH LRK10 LIGHTING RETROFIT KIT

• Designed for professionals who routinely audit existing and replacement lighting systems for energy efficiency and lighting performance
• Kit includes:
• LT300 - Light meter with digital and analog display of light in Foot-candles or Lux
• DT200 - Compact laser distance meter with area/volume calculation functions
• Supplied in a soft carrying case that provides protection and organization for the meters whenever they are needed

 

EXTECH 380260 AUTORANGING DIGITAL MEGOHMMETER

• 250V, 500V, and 1000V test voltages
• Insulation Resistance to 2000MOhm
• Lo Ohm function for testing connections
• Lock Power On Function for hands-free operation

 

EXTECH EMF300 MICROWAVE LEAKAGE DETECTOR

• Ideal for measuring high frequency radiation levels emitted from household and commercial microwave ovens
• 0 to 1.999mW/cm² measurement range
• Audible alarm and overrange indicator
• Peak Hold
• Complete with 9V battery

 

EXTECH EX230 12 FUNCTION MINI DIGITAL MULTIMETER WITH IR THERMOMETER

• Built-in IR Thermometer with laser pointer for locating hot spots (6:1 Distance to Target Ratio)
• AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Temperature (Type K + IR), Duty Cycle, Continuity / Diode
• 4000 count large backlit dual LCD with easy-to read digits
• Low current capability measure down to 0.1µA

 

EXTECH 382203 ANALOG TRIPLE OUTPUT DC POWER SUPPLY

• Adjustable Voltage and Current output
• Easy snap terminals for fixed 5V/0.5A and 12V/1A outputs
• Constant Voltage or Current
• Current limiting indicator
• Overload and short circuit protection
• Binding post terminals for variable supply