High Performance Power Filters for Tempest/ RFI/ EMI test currents 6..100A ETS-Lindgren N255X

Code: ETS-Lindgren N255X


 

Datasheet PDF, 0.27 Mb

Description

  • Maximum protection in Tempest and EMPP applications
  • Highest performing commercially available power line filter
  • Over 100dB insertion loss from 10 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • High performance screen rooms, providing attenuation of both the incoming and outgoing mains supply lines to match the shield performance
  • Tempest applications, where the very highest degree of protection is required to obtain maximum security
  • EMP protection systems

 

Electrical Specifications

Part #

Current Max

Frequency

Max Voltage

# of Lines

Voltage Drop On Full Load in 250V 50/50Hz System/Line

DC Resistance Per Line

N2550

6 A

50/60 Hz

250 V

2

1 V

50 O

N2551

6 A

50/60 Hz

440/250 V

4

1 V

50 O

N2552

16 A

50/60 Hz

250 V

2

1 V

12 O

N2553

16 A

50/60 Hz

440/250 V

4

1 V

12 O

N2554

32 A

50/60 Hz

250 V

2

0.6 V

24 O

N2555

32 A

50/60 Hz

440/250 V

4

0.6 V

24 O

N2556

63 A

50/60 Hz

250 V

2

1.5 V

15 O

N2557

63 A

50/60 Hz

440/250 V

4

1.5 V

15 O

N2558

100 A

50/60 Hz

250 V

2

0.9 V

5 O

N2559

100 A

50/60 Hz

440/250 V

4

0.9 V

5 O

 

More products ETS-LINDGREN

VLF MAGNETIC FIELD SURVEY METER 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5402

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

HYBRID LOG PERIODIC BROADBAND ANTENNA FOR EMC MEASUREMENTS 80 MHZ..6 GHZ ETS-LINDGREN 3149

• Frequency Minimum 80 MHz
• Frequency Maximum 6 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 750 W..200 W
• Pattern Type directional
• Polarization linear
• VSWR 6.5:1 max

 

HIGH GAIN CONICAL HORN ANTENNA WITH LINEAR POLARIZATION 4..26.5 GHZ ETS-LINDGREN 3163

• Conical Shape
• Series Frequency Range: 4 GHz to 26.5 GHz
• High Gain
• Low VSWR

 

MAGNETIC SHIELDED COIL ANTENNA LOW FREQUENCIES 30 HZ..100 KHZ ETS-LINDGREN 7605/ 7606

• Frequency Minimum 30 Hz
• Frequency Maximum 100 kHz
• Connectors Banana Jack (2) - [7605], BNC - [7606]
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

ACOUSTIC TEST ENCLOSURE FOR SMALL DEVICES ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

SHIELDED TEST CELL ENCLOSURE FOR WIRELESS MEASUREMENTS ETS-LINDGREN 5247

• Roll-About Casters
• Portable RF Shielded Enclosure for OTA measurements
• >80 dB Typical RF Isolation
• RF Absorber Lined
• Dual Polarized Horn Antenna
• 700 MHz - 10 GHz Frequency Range
• Linear & Circular Polarization

 

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 20 HZ..5 MHZ ETS-LINDGREN 6511

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear