High Performance Power Filters for Tempest/ RFI/ EMI test currents 6..100A ETS-Lindgren N255X

Code: ETS-Lindgren N255X


 

Datasheet PDF, 0.27 Mb

Description

  • Maximum protection in Tempest and EMPP applications
  • Highest performing commercially available power line filter
  • Over 100dB insertion loss from 10 kHz to 10 GHz
  • Fully accessible end chambers
  • RoHS compliant and CE marked for compliance with the low voltage directive

 

Applications

  • High performance screen rooms, providing attenuation of both the incoming and outgoing mains supply lines to match the shield performance
  • Tempest applications, where the very highest degree of protection is required to obtain maximum security
  • EMP protection systems

 

Electrical Specifications

Part #

Current Max

Frequency

Max Voltage

# of Lines

Voltage Drop On Full Load in 250V 50/50Hz System/Line

DC Resistance Per Line

N2550

6 A

50/60 Hz

250 V

2

1 V

50 O

N2551

6 A

50/60 Hz

440/250 V

4

1 V

50 O

N2552

16 A

50/60 Hz

250 V

2

1 V

12 O

N2553

16 A

50/60 Hz

440/250 V

4

1 V

12 O

N2554

32 A

50/60 Hz

250 V

2

0.6 V

24 O

N2555

32 A

50/60 Hz

440/250 V

4

0.6 V

24 O

N2556

63 A

50/60 Hz

250 V

2

1.5 V

15 O

N2557

63 A

50/60 Hz

440/250 V

4

1.5 V

15 O

N2558

100 A

50/60 Hz

250 V

2

0.9 V

5 O

N2559

100 A

50/60 Hz

440/250 V

4

0.9 V

5 O

 

More products ETS-LINDGREN

EMC AND RF MICROWAVE ABSORBERS ETS-LINDGREN

• EMC Anechoic Absorber
• Ferrite Tile Absorber
• FerroSorb FS EMC Absorber
• FerroSorb PS EMC Absorber
• Ultra Broadband Microwave Absorber

 

HIGH PERFORMANCE CONTROL FILTERS FOR TEMPEST/ EMP/ EMI APPLICATIONS CURRENTS 2..10A ETS-LINDGREN N502X/ N503X

• Current Rating 2 Amps
• Number of Lines 2
• Voltage Frequency Maximum 100/DC
• Current range up to 10 Amperes
• Protection for Tempest and EMP
• Low volt drop
• AC and DC Options

 

BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184

• Frequency Minimum 1 GHz
• Frequency Maximum 18 GHz
• VSWR Ratio (AVG) 2:1
• Maximum Continuous Power 50 watts @ 1 GHz, 25 watts @ 18 GHz
• Broadband Spectrum Monitoring
• Harmonics Level Measurement IEC 61000-4-3

 

ELECTROMAGNETIC LEAKAGE METER OF MICROWAVE OVENS ETS-LINDGREN HI-1600

• Calibrated at 915 MHz and 2450 MHz
• Three Ranges

 

E-FIELD GENERATOR LINEAR POLARIZED 10 KHZ..30 MHZ ETS-LINDGREN 3107B

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 1000 W
• Peak Power 1500 W
• Polarization linear
• Linear Polarization

 

DOUBLE-RIDGET HORN ANTENNA FOR EMC MEASUREMENTS 18..40 GHZ ETS-LINDGREN 3116B

• Frequency Minimum 18 GHz
• Frequency Maximum 40 GHz
• VSWR Ratio (AVG) 2.5:1 max
• Maximum Continuous Power 20 W
• Peak Power 200 W
• Impedance (Nominal) 50 ?

 

WLAN ACCES POINT TEST ENCLOSURE ETS-LINDGREN 5225

• Works with 802.11 Traffic Generator and Performance Analyzers
• Tests:
• -- Over-The-Air Performance of TX, RX
• -- Wireless LAN Access Point Throughput Performance
• Flat Coupling Response over 2.2GHz - 2.6GHz, 5.2GHz - 6.0GHz

 

ACOUSTIC TEST ENCLOSURE FOR SMALL DEVICES ETS-LINDGREN SD

• Acoustically Controlled Test Environment
• Survey and/or Engineering Grade Measurement
• Applicable Test Standards: ISO 30744, GM W7293, GM W14011

 

RF ELECTROMAGNETIC SURVEY METER ETS-LINDGREN HI-2200

• Handstrap & Safety Lanyard Mount
• Optional Fiber Optic Link
• Interchangeable Probe Heads
• Small/Lightweight for minimal field perturbance
• Broadband Frequency Range
• Economical Solution to Broadcast/Telecom Safety Monitoring Needs & Environmental Monitoring

 

ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity