Code: ETS-Lindgren 95236-1/ 95242-1
Description
The probe's operating frequency range is 10 kHz to 100 MHz. This probe is most efficient from about 15 kHz to 4 MHz. The 95236-1 probe cover the low frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (10 kHz · Z MHz).
The Model 95236-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
10 kHz |
|
Frequency Maximum |
100 MHz |
|
Maximum Power |
100 W |
It enables testing to be performed which previously required the use of two separate injection probes, the ERA type 36A and 37A This is our most efficient injection device from 4 MHz to almost 600 MHz The 95242-1 probe covers the high frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (5 MHz - 400 MHz). This injection probe is also suitable for injecting the required current waveforms of MIL-STD-461D limits CS115 and CS116 (for CS116, one of our lower frequency probes is required as well). Testing to British Defense Standard DEF STA 59-41, Part 3 is also supported by this model. When necessary, our 95235-1 injection probe has larger 2.625" window diameter, but is less efficient than the 95242-1. When calibrating the Calibration Jig coupled current vs. forward power into the injection probe, the combination of 95242-1 probe and 95241-1 Jig has an excellent low VSWR.
The Model 95242-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
2 MHz |
|
Frequency Maximum |
400 MHz |
|
Maximum Power |
100 W |
More products ETS-LINDGREN
|
DOUBLE-RIDGET HORN ANTENNA FOR EMC MEASUREMENTS 18..40 GHZ ETS-LINDGREN 3116B
• Frequency Minimum 18 GHz |
|
BICONICAL PRECISION MEASUREMENT ANTENNA 30..300 MHZ ETS-LINDGREN 3110C
• Frequency Minimum 30 MHz |
|
DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 400 MHZ..6 GHZ ETS-LINDGREN 3119
• Frequency Minimum 400 MHz |
|
DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B
• Frequency Minimum 200 MHz |
|
BROADBAND OMNIDIRECTIONAL ANTENNA FOR SPECTRUM MONITORING 500 MHZ..18 GHZ ETS-LINDGREN 3181
• Frequency Minimum 500 MHz |
|
PORTABLE TEST ENCLOSURE FOR EMI/RFI TEST ETS-LINDGREN 5240
• Ease of operation in a compact, portable format |
|
HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X
• Maximum protection in Tempest and EMPP applications |
|
BICONICAL LINEAR POLARIZED ANTENNA 30..100 MHZ ETS-LINDGREN 3159
• Frequency Minimum 30 MHz |
|
CURRENT MEASUREMENT PROBES 10 KHZ..1000 MHZ ETS-LINDGREN
• 10 kHz..1000 MHz Frequency ranges |
|
BROADBAND BICONICAL ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3182
• Frequency Minimum 30 MHz |