Code: ETS-Lindgren 95236-1/ 95242-1
Description
The probe's operating frequency range is 10 kHz to 100 MHz. This probe is most efficient from about 15 kHz to 4 MHz. The 95236-1 probe cover the low frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (10 kHz · Z MHz).
The Model 95236-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter, exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
10 kHz |
|
Frequency Maximum |
100 MHz |
|
Maximum Power |
100 W |
It enables testing to be performed which previously required the use of two separate injection probes, the ERA type 36A and 37A This is our most efficient injection device from 4 MHz to almost 600 MHz The 95242-1 probe covers the high frequency portion of RTCA/DO-160C RF conducted susceptibility requirements and MIL-STD-461D I MIL-STD-462D CS114 (5 MHz - 400 MHz). This injection probe is also suitable for injecting the required current waveforms of MIL-STD-461D limits CS115 and CS116 (for CS116, one of our lower frequency probes is required as well). Testing to British Defense Standard DEF STA 59-41, Part 3 is also supported by this model. When necessary, our 95235-1 injection probe has larger 2.625" window diameter, but is less efficient than the 95242-1. When calibrating the Calibration Jig coupled current vs. forward power into the injection probe, the combination of 95242-1 probe and 95241-1 Jig has an excellent low VSWR.
The Model 95242-1 probe has a 1.6" window, making it suitable for injecting current into most power or signal cables. (AWG 4/0 cable, good for several hundred Amps, is 12.7 mm (0.5 in) diameter exclusive of insulation.) 100 Watts of cw RF power may be driven into the probe in the injection mode.
|
Frequency Minimum |
2 MHz |
|
Frequency Maximum |
400 MHz |
|
Maximum Power |
100 W |
More products ETS-LINDGREN
|
BROADBAND BICON ANTENNA WITH RADOME PROTECTION 1..18 GHZ ETS-LINDGREN 3184
• Frequency Minimum 1 GHz |
|
RF ATTENUATION AND ELECTROMAGNETIC SHIELDING METER 8..64 MHZ ETS-LINDGREN MF-130D
• Measurement frequencies: 8 MHz, 16 MHz, 32 MHz and 64 MHz |
|
MULTI-OCTAVE PYRAMIDAL HORN ANTENNA LINEAR POLARIZED 960 MHZ..40 GHZ ETS-LINDGREN 3160
• Frequency Minimum 960 MHz |
|
REVERBERATION TEST CELL FOR RADIATED IMMUNITY AND EMISSIONS MEASUREMENTS ETS-LINDGREN SMART 1000
• Automated Measurement with Optional Software |
|
DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B
• Frequency Minimum 200 MHz |
|
BROADBAND E-FIELD MONITORING SYSTEM 10 KHZ..40 GHZ ETS-LINDGREN HI-6100 E-FIELD MONITOR
• HI-6100 Field Monitor with 4 Probe Input Channels |
|
HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X
• Suitable for 400Hz supplies |
|
POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X
• Current Rating 6 Amps |
|
POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION WITH LOW EARTH LEAKAGE CURRENTS 6..100A ETS-LINDGREN N242X
• Suitable for mobile installations |
|
RF ELECTROMAGNETIC SURVEY METER ETS-LINDGREN HI-2200
• Handstrap & Safety Lanyard Mount |