Electromagnetic Leakage Meter of Microwave Oven ETS-Lindgren HI-1501

Code: ETS-Lindgren HI-1501


 

Datasheet PDF, 0.09 Mb

Description

  • Three Ranges
  • Calibrated at 2450 MHz
  • Battery Operated
  • Extra sensitivity for Compliance Measurement

 

Electrical Specifications

Frequency

2450 MHz

Maximum Power Density

2.0 W/cm2

Ranges

0-2, 0-10, 0-100 mW/cm

Response Time

Fast Mode: 1 second.
Slow Mode: 2.5 secs (to 90% of Impulse Level)

 

Standard accessories

  • Fitted Carry Case
  • User Manual
 

Recommended options

  • Plastic Beaker, 600 ml.
  • Spacer Cone/Shield Kit
 

More products ETS-LINDGREN

BICONICAL LINEAR POLARIZED ANTENNA 30..100 MHZ ETS-LINDGREN 3159

• Frequency Minimum 30 MHz
• Frequency Maximum 100 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 15 kW
• Pattern Type omnidirectional
• Polarization linear

 

ELECTRIC FIELD MEASUREMENT PROBES 500 KHZ..5 GHZ ETS-LINDGREN HI-4433

• Frequency Range: 500kHz - 5GHz
• Automatic Continuous Zeroing
• Fiber Optic Technology
• Dynamic Range down to 300 mA/m
• Data from each axis can be viewed individually

 

UNIFORM VERTICAL ELECTRIC FIELD GENERATOR 10 KHZ..30 MHZ ETS-LINDGREN 5503

• Generates large area uniform vertical electric field
• 10 kHz - 30 MHz frequency range
• Accommodates various EUT sizes with adjustable height feature
• Temperature maintained with external forced-air cooling, and monitored by temperature sensor
• Easy to assemble/disassemble and remove from the chamber

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMP APPLICATIONS CURRENTS 16..200A ETS-LINDGREN N600X

• Suitable for 400Hz supplies
• Compact Rugged Construction
• Maximum Protection for EMP and Tempest applications
• Current Range 16 to 200 Amperes
• 100 dB Insertion Loss from 14 kHz to 40 GHz
• Low power dissipation

 

DUAL POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1.1 GHZ ETS-LINDGREN 3145BDP

• Frequency Range 100 MHz - 1.1 GHz
• Input Impedance 50 ?
• VSWR 1.5:1 average, 3.5:1 maximum
• Maximum RF input power 800 W
• Stainless Steel Construction
• Dual Linearly Polarized

 

ELECTROMAGNETIC FIELD EMISSION METER OF ELECTRIC TRANSMISSION ELECTRIC POWER LINES ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3164-01

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• VSWR Ratio (AVG) 3:1 maximum
• 1.75:1 average
• Maximum Continuous Power 750 watts @ 100 MHz
• 200 watts @ 1 GHz
• Impedance (Nominal) 50 ?
• Connectors (2) Type N Female

 

RF SHIELDED TEST ENCLOSURE FOR EMC TEST ETS-LINDGREN 5230

• Standard dimenssions 600 x 500 x 500 mm
• Progressive Latching
• Large Working Interior
• Up to 120 dB RF Isolation

 

ABSORBER NESTED DUAL-POLARIZED DUAL-VIVALDI ARRAY ANTENNA 700 MHZ..6 GHZ ETS-LINDGREN 3165-01

• Frequency Minimum 700 MHz
• Frequency Maximum 6 GHz
• Cross Polarization Isolation > 25 dB
• Impedance 50 ?
• Low Reflectivity
• Dual Linearly Polarized
• Low VSWR with High Directivity

 

ELECTROMAGNETIC FIELD EMISSION MEASURING TESTER OF VIDEO DISPLAYS ETS-LINDGREN HI-3603

• VDT / VLF Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging