BAUR PGK 70 HB High-voltage test device

Code: BAUR PGK 70 HB


 

Datasheet PDF, 0.35 Mb

Description

There are hardly any other longer-lasting, more robust and cost-effective testing devices than the two-piece high-voltage test devices from the PGK HB series. They generate continuous adjustable test voltages with mains frequency or optionally DC with positive or negative polarity. The display instruments for current and voltage, the safety control unit and the regulating transformer for the voltage are integrated in the operating unit.

 

Features:

  • Testing of medium- and high-voltage cables
  • DC voltage testing of up to 70 kV output voltage with positive or negative polarity
  • AC voltage testing - up to 55 kV for switchgear, busbars and insulating elements
  • Easy-to-maintain 2-piece design
 

More products BAUR

BAUR PGK 50E / PGK 80E DC HIGH-VOLTAGE TEST DEVICE

• Continuous adjustable output voltage
• The voltage measurement is done directly at the high voltage output
• Timer of 1-30 min
• Sensitive current measurement for recording the smallest of insulation currents with 6-time range switch, decadal

 

BAUR CL 20 CABLE LOCATOR

• Fast and exact location of position and laying depth of cables
• Intuitive operation ½ no special measurement knowledge required
• Lightweight and manageable

 

BAUR PD-SGS HANDHELD ONLINE PD DETECTOR

• Initial rapid condition evaluation of switchgear and cable accessories during mains operation
• Ideal for quick checks of MV and HV switchgear

 

BAUR SYSCOMPACT 2000 MOBILE CABLE FAULT LOCATION SYSTEM

• Fast and reliable
• Precise, dependable cable fault location
• High performance high voltage unit
• Integrated proven cable fault pre-location methods

 

BAUR PAULA PHASE DETECTOR

• Clear phase determination possible in cable lengths up to 40 km
• Highest level of safety when used on earthed and shorted cables in compliance with EN 50110-1 (DIN VDE 0105-100)
• Suitable for all switchgear constructions due to compact design of the signal injectors
• Ready for operation for up to 2 weeks (standby mode)

 

BAUR ATG 2 BURN DOWN TRANSFORMER

• Portable device for changing the fault resistance
• Useful for cables that are difficult to access
• Proven methods for complicated faults
• Independent current and voltage control on each burning level

 

BAUR SHIRLA CABLE SHEATH TESTING AND FAULT LOCATION SYSTEM

• Cable and cable sheath testing up to 10 kVC
• Resistance measurement
• Cable and cable sheath fault pre-location with precision measuring bridge
• Adjustable cable sections that can be defined with length, conductor cross-section and material respectively and can be considered in the distance calculation

 

BAUR DPA 75 C OIL BREAKDOWN VOLTAGE TESTER

• Compact and robust device for portable use onsite
• Test voltages from 0 to 75 kVrms
• Repeatable breakdown measurements in mineral, silicone and plant oils
• Reliable measurement results due to its short switch-off time (< 10 ½s)

 

BAUR SYSCOMPACT 2000 M PRO

• Fully integrated proven cable fault pre-location methods
• Surge mode for acoustic pin-pointing
• Easily transportable
• Ideal for locations that are difficult to access

 

BAUR IRG 2000 TIME DOMAIN REFLECTOMETER

• Easy and quick cable fault location
• Light, compact and manageable
• Main unit for the tried-and-tested pre-location method
• Ideal for integration in measurement systems