• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification • is an instrument for direct measurement of solar irradiance (Watt/m2).• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays. • By using suitable diaphragms only the direct light reaches the surface of the sensor. • According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.
• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm). • mV per mW/cm2 output.• Complete with Calibration Report. • On request 5 or 10m cables with connectors
• LP NET 07 measures the net radiation across a surface, from near ultraviolet to• far infrared. • The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer. • The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.• The instrument is designed and constructed to be used outdoors in any weather• conditions.
• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?• equipped with a temperature sensor (NTC).
• pHmeter-Thermometer which measures pH, mV and temperature. • Storage of maximum, minimum, average value. • Functions: REL, HOLD and auto power off which can be disabled, • IP 67 protection degree.
• pHmeter-Thermometer which measures pH, mV and temperature. • Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples. • RS232 C/ USB output for data transfer in real time to a PC or printer. • Functions: REL, HOLD and auto power off which can be disabled, • IP 67 protection degree.
• pH/mV simulator kit composed of instrument HD9609, • adapter cables CP 9509/T, • CP9509/BNC and • carrying case.
• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature. • Storage of maximum, minimum, average value. • Functions: REL, HOLD and auto power off which can be disabled, • IP 67 protection degree.
• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature. • Datalogger which can store the maximum, minimum, average value and can store up to 36,000 samples. • RS232 C/ USB output for data transfer in real time to a PC or printer. • Functions: REL, HOLD and auto power off which can be disabled, • IP 67 protection degree.
• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature. • Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements. • USB output for data transfer in real time to a PC or printer.• Functions: REL, HOLD and auto power off which can be disabled, • IP 67 protection degree.
• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature. • Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples. • RS232 C/ USB output for data transfer in real time to a PC or printer. • Functions: REL, HOLD and auto power off which can be disabled, • IP 67 protection degree.
• portable multi-parameter data logger for electrochemical measures: pH, conductivity, dissolved oxygen and temperature• large back-lighted LCD display• pH, mV, redox potential (ORP) with pH, redox or combined pH/temperature electrodes complete with SICRAM module• conductivity, resistivity in liquids, total dissolved solids (TDS), and salinity with combined 4-ring and 2-ring conductivity and temperature probes with SICRAM module.• Concentration of dissolved oxygen in liquids (in mg/l), saturation index (in %)
• Bench-top pHmeter-Thermometer with back-lighted display, • with two BNC inputs, to • measure pH, mV, ORP with pH, redox, separated reference electrodes, • one input for a pH/temperature combined probe provided with SICRAM module. • Datalogger of pH, mV, temperature. • RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time. • Input for Pt100 or Pt1000 temperature probes provided with SICRAM module
• Bench-top conductivity meter-Thermometer with back-lighted display, • with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature • combined probes with 2 or 4 electrodes with direct input or with SICRAM module. • Datalogger of conductivity or resistivity or TDS and temperature. • RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time. • Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.
• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display, • to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe, • it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with • 2 or 4 electrodes with direct input or with SICRAM module. • Datalogger for pH or mV, conductivity or resistivity or TDS and temperature. • RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity, • total dissolved solids (TDS) and salinity by 2 or 4 electrodes, • combined conductivity probes and temperature by Pt100 or Pt1000 probes.• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples. • RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time. • Functions: REL, HOLD, auto power off which can be disabled., • protection degree IP 66
• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature. • It is are fitted with a large backlighted LCD display.• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference; • conductivity, resistivity in liquids, • total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/• temperature probes with direct input or SICRAM module; • concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),
• Bench-top Oxymeter-Thermometer measures dissolved oxygen, • saturation index by polarographic type combined probes, • temperature by Pt100 probes with SICRAM module. • Datalogger which stores maximum, minimum, average value. • RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time. • Functions: REL, HOLD, auto power off which can be disabled, • protection degree IP 66
• Bench-top pHmeter-Conductivity meter-Thermometer • measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity, • liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes. • Datalogger which stores maximum, minimum, average value. • RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time. • Functions: REL, HOLD, auto power off which can be disabled, • protection degree IP 66
• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources • it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC. • Automatic calibration, • datalogger, • data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11