Three-Channel Vibration Analyzer for workers protection Delta Ohm HD2070

Code: Delta Ohm HD2070


 

Datasheet PDF, 0.82 Mb
                 

Description

The HD2070 is a portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously. The instrument measures all parameters required by current regulations concerning workers protection from vibration related risks and is able to measure vibrations transmitted to both hand-arm and whole body. It has been designed combining simplicity of use with maximum flexibility and the possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement. 

 

The HD2070 vibration analyzer conforms to the following standards:

• ISO 8041:2005 "Human response to vibration - Measuring instrumentation"

• ISO 5349-1:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - General requirements"

• ISO 5349-2:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Practical guidance for measurement at the workplace"

• ISO 2631-1:1997 "Mechanical vibration and shock - Evaluation of human exposure to whole body vibration - General requirements"

• ISO 2631-2:1989 "Evaluation of human exposure to whole body vibration - Continuous and shock-induced vibrations in buildings (1 to 80 Hz)"

• IEC 61260:1995 "Electro- acoustics - Octave band and fractional-octave band filters" (option HD2070.O1)

 

 

Main features

• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard.

• The HD2070 detects accelerations on three axes with integrated amplifying electronics (IEPE or equivalent type); it is possible to connect three singleaxes or one tri-axial accelerometer to the instrument. Accelerometers with integrate electronics allow to achieve low impedance and low noise connections between the accelerometer and the instrument, decreasing the probability to get wrong or altered measurements because of interferences or electromagnetic disturbances.

• The HD2070 analyzes the signals coming from the accelerometer and makes calculations simultaneously on three axes; it calculates the weighted acceleration values as well as the octave or third octave spectra (with option HD2070.O1). Acceleration, velocity or displacement values can be shown for each frequency band. Frequency weightings can be freely chosen according to the specific application.

• Together with values of instantaneous and mean acceleration, the analyzer calculates in addition peak levels, vibration dose (VDV), crest factors and performs statistical analysis (option HD2070.O2).

• As statistical analyzer, the HD2070 calculates, with option HD2070.O2, the probability distribution of a measurement parameter in 1dB classes. Both the probability distribution and the percentile levels from L1 to L99 are available as graphs.

• A versatile data logging function stores multiple profiles and spectra using either the internal memory of 8MB or memory card (MMC or SD cards up to 2GB). Each record can be documented with a voice comment. In addition, the HD2070 can be used as an audio recorder, as a further opportunity to document the measures.

• With the option HD2070.O3 you can add to the profiles also the signals provided by accelerometers, recording the digital samples directly. When the stored data are analyzed, it is useful to examine the accelerometer signals to verify the absence of artefacts such as, for example, those associated with the phenomenon of DC-shift.

• The "Navigator" program available in the analyzer allows to examine logged measurements and to hear vocal comments.

• For a quick setup of the instrument it is possible to store up to nine setup, user-customized according to specific applications. The desired setup is easily identified by the associated title.

• The calibration can be performed using either the calibration data of the accelerometers with a vibration generator. The last 120 calibrations performed are recorded in a file and stored in a protected and reserved area of the permanent memory of the instrument. The program interface Noise Studio automatically adds the file supplied with the calibration measurements during the downloading of data into the PC memory.

• HD2070 can be completely controlled by a PC, via RS232 and USB serial interfaces, using a special communication protocol.

 

More products SENSECA

INTEGRATING SOUND LEVEL METER CLASS I OR CLASS II WITH SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC

• integrating portable sound level meter performing statistical analysis
• maximum low cost and simplicity of use
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 dated 2002, IEC 60651 and IEC 60804
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis

 

LOGGING INSTRUMENT FOR CO, CO2, ATMOSPHERIC PRESSURE, TEMPERATURE, HUMIDITY DELTA OHM HD21AB HD21AB17

• Carbon Dioxide CO2
• Carbon Monoxide CO
• Atmospheric Pressure
• Temperature
• Relative Humidity
• Dew Point, Wet Bulb Temperature, Absolute Humidity, Mixing Ratio, Enthalpy

 

CLASS I AUDIO ANALYZER WITH DATALOGGER, THIRD OCTAVE SPECTRUM ANALYSIS, STATISTICS DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

DATALOGGER FOR PRESSURE, TEMPERATURE, FLOW RATE DELTA OHM DO9704

• Datalogger for pressure, flow rate and temperature measurements with 2 inputs,
• memory 512 Kbytes,
• storage of maximum, minimum and average value.
• RS232 C output

 

DATALOGGER PHOTO-RADIOMETER FOR SOLAR LIGHT, TEMPERATURE DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

NET RADIOMETER FOR ULTRAVIOLET TO INFRARED SOLAR RADIATION MEASUREMENT DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

MULTIPARAMETRIC PH-METER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

ANEMOMETER-THERMOMETER DELTA OHM HD2103.1 HD2103.2

• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module.
• Datalogger which stores the maximum, minimum, average value and can store up to 38,000 samples.
• RS232C/USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP67 protection degree.