Three-Channel Vibration Analyzer for workers protection Delta Ohm HD2070

Code: Delta Ohm HD2070


 

Datasheet PDF, 0.82 Mb
                 

Description

The HD2070 is a portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously. The instrument measures all parameters required by current regulations concerning workers protection from vibration related risks and is able to measure vibrations transmitted to both hand-arm and whole body. It has been designed combining simplicity of use with maximum flexibility and the possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement. 

 

The HD2070 vibration analyzer conforms to the following standards:

• ISO 8041:2005 "Human response to vibration - Measuring instrumentation"

• ISO 5349-1:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - General requirements"

• ISO 5349-2:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Practical guidance for measurement at the workplace"

• ISO 2631-1:1997 "Mechanical vibration and shock - Evaluation of human exposure to whole body vibration - General requirements"

• ISO 2631-2:1989 "Evaluation of human exposure to whole body vibration - Continuous and shock-induced vibrations in buildings (1 to 80 Hz)"

• IEC 61260:1995 "Electro- acoustics - Octave band and fractional-octave band filters" (option HD2070.O1)

 

 

Main features

• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard.

• The HD2070 detects accelerations on three axes with integrated amplifying electronics (IEPE or equivalent type); it is possible to connect three singleaxes or one tri-axial accelerometer to the instrument. Accelerometers with integrate electronics allow to achieve low impedance and low noise connections between the accelerometer and the instrument, decreasing the probability to get wrong or altered measurements because of interferences or electromagnetic disturbances.

• The HD2070 analyzes the signals coming from the accelerometer and makes calculations simultaneously on three axes; it calculates the weighted acceleration values as well as the octave or third octave spectra (with option HD2070.O1). Acceleration, velocity or displacement values can be shown for each frequency band. Frequency weightings can be freely chosen according to the specific application.

• Together with values of instantaneous and mean acceleration, the analyzer calculates in addition peak levels, vibration dose (VDV), crest factors and performs statistical analysis (option HD2070.O2).

• As statistical analyzer, the HD2070 calculates, with option HD2070.O2, the probability distribution of a measurement parameter in 1dB classes. Both the probability distribution and the percentile levels from L1 to L99 are available as graphs.

• A versatile data logging function stores multiple profiles and spectra using either the internal memory of 8MB or memory card (MMC or SD cards up to 2GB). Each record can be documented with a voice comment. In addition, the HD2070 can be used as an audio recorder, as a further opportunity to document the measures.

• With the option HD2070.O3 you can add to the profiles also the signals provided by accelerometers, recording the digital samples directly. When the stored data are analyzed, it is useful to examine the accelerometer signals to verify the absence of artefacts such as, for example, those associated with the phenomenon of DC-shift.

• The "Navigator" program available in the analyzer allows to examine logged measurements and to hear vocal comments.

• For a quick setup of the instrument it is possible to store up to nine setup, user-customized according to specific applications. The desired setup is easily identified by the associated title.

• The calibration can be performed using either the calibration data of the accelerometers with a vibration generator. The last 120 calibrations performed are recorded in a file and stored in a protected and reserved area of the permanent memory of the instrument. The program interface Noise Studio automatically adds the file supplied with the calibration measurements during the downloading of data into the PC memory.

• HD2070 can be completely controlled by a PC, via RS232 and USB serial interfaces, using a special communication protocol.

 

More products SENSECA

INDOOR QUALITY ANALYSIS IAQ MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

MICRO MANOMETER-THERMOMETER DELTA OHM HD2114P HD2134P

• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes
• full scale 20mbar for speed measurements from 2...55m/s.
• Temperature measurement by K type thermocouple.
• Datalogger which stores the maximum, minimum, average value and can store up to 36,000 couples of samples.
• RS232C/ USB output for data transfer in real time to a PC or printer

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

SECONDARY CLASS PYRANOMETER FOR DIRECT SOLAR IRRADIANCE ON FLAT SURFACE AND GLOBAL RADIATION DELTA OHM LP PYRA10

• measures the irradiance on a flat surface (Watt/m2)
• pyranometer classified as Secondary in accordance with ISO 9060
• according to the publication "Guide to Meteorological Instruments and Methods of Observation", fifth edition (1983) of WMO
• LP PYRA 10 PASSIVE *
• LP PYRA 10 AC ACTIVE with CURRENT 4..20 mA output
• LP PYRA 10 AV ACTIVE with VOLTAGE 0..1 V, 0..5 V, 0..10 V output

 

DATALOGGER FOR PRESSURE, TEMPERATURE, FLOW RATE DELTA OHM DO9704

• Datalogger for pressure, flow rate and temperature measurements with 2 inputs,
• memory 512 Kbytes,
• storage of maximum, minimum and average value.
• RS232 C output

 

CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2306.0

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

LABORATORY BENCH PHMETER-THERMOMETER WITH PH, MV, REDOX POTENTIAL DELTA OHM HD2205.2

• Bench-top pHmeter-Thermometer with back-lighted display,
• with two BNC inputs, to
• measure pH, mV, ORP with pH, redox, separated reference electrodes,
• one input for a pH/temperature combined probe provided with SICRAM module.
• Datalogger of pH, mV, temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module

 

MONO-AXIAL ACCELEROMETER AND TRIAXIAL ACCELEROMETER ICP MECHANICAL VIBRATIONS DELTA OHM

• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system
• HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system
• HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body
• HD356A22: tri-axial accelerometer for general application
• HD352C34: mono-axial accelerometer for general application
• HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.