Three-Channel Vibration Analyzer for workers protection Delta Ohm HD2070

Code: Delta Ohm HD2070


 

Datasheet PDF, 0.82 Mb
                 

Description

The HD2070 is a portable vibration analyzer performing spectral and statistical analysis on three channels simultaneously. The instrument measures all parameters required by current regulations concerning workers protection from vibration related risks and is able to measure vibrations transmitted to both hand-arm and whole body. It has been designed combining simplicity of use with maximum flexibility and the possibility of updating the instrument according to the evolution of the regulations relating to vibration measurement. 

 

The HD2070 vibration analyzer conforms to the following standards:

• ISO 8041:2005 "Human response to vibration - Measuring instrumentation"

• ISO 5349-1:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - General requirements"

• ISO 5349-2:2001 "Mechanical vibration - Measurement and evaluation of human exposure to hand-transmitted vibration - Practical guidance for measurement at the workplace"

• ISO 2631-1:1997 "Mechanical vibration and shock - Evaluation of human exposure to whole body vibration - General requirements"

• ISO 2631-2:1989 "Evaluation of human exposure to whole body vibration - Continuous and shock-induced vibrations in buildings (1 to 80 Hz)"

• IEC 61260:1995 "Electro- acoustics - Octave band and fractional-octave band filters" (option HD2070.O1)

 

 

Main features

• Octave and third octave filters, available as option (HD2070.O1), satisfy class 1 specifications of IEC 61260 standard.

• The HD2070 detects accelerations on three axes with integrated amplifying electronics (IEPE or equivalent type); it is possible to connect three singleaxes or one tri-axial accelerometer to the instrument. Accelerometers with integrate electronics allow to achieve low impedance and low noise connections between the accelerometer and the instrument, decreasing the probability to get wrong or altered measurements because of interferences or electromagnetic disturbances.

• The HD2070 analyzes the signals coming from the accelerometer and makes calculations simultaneously on three axes; it calculates the weighted acceleration values as well as the octave or third octave spectra (with option HD2070.O1). Acceleration, velocity or displacement values can be shown for each frequency band. Frequency weightings can be freely chosen according to the specific application.

• Together with values of instantaneous and mean acceleration, the analyzer calculates in addition peak levels, vibration dose (VDV), crest factors and performs statistical analysis (option HD2070.O2).

• As statistical analyzer, the HD2070 calculates, with option HD2070.O2, the probability distribution of a measurement parameter in 1dB classes. Both the probability distribution and the percentile levels from L1 to L99 are available as graphs.

• A versatile data logging function stores multiple profiles and spectra using either the internal memory of 8MB or memory card (MMC or SD cards up to 2GB). Each record can be documented with a voice comment. In addition, the HD2070 can be used as an audio recorder, as a further opportunity to document the measures.

• With the option HD2070.O3 you can add to the profiles also the signals provided by accelerometers, recording the digital samples directly. When the stored data are analyzed, it is useful to examine the accelerometer signals to verify the absence of artefacts such as, for example, those associated with the phenomenon of DC-shift.

• The "Navigator" program available in the analyzer allows to examine logged measurements and to hear vocal comments.

• For a quick setup of the instrument it is possible to store up to nine setup, user-customized according to specific applications. The desired setup is easily identified by the associated title.

• The calibration can be performed using either the calibration data of the accelerometers with a vibration generator. The last 120 calibrations performed are recorded in a file and stored in a protected and reserved area of the permanent memory of the instrument. The program interface Noise Studio automatically adds the file supplied with the calibration measurements during the downloading of data into the PC memory.

• HD2070 can be completely controlled by a PC, via RS232 and USB serial interfaces, using a special communication protocol.

 

More products SENSECA

RAIN DETECTOR AND ATHMOSPHERICAL PRECIPITATION DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

LABORATORY ELECTROCHEMICAL MULTIPARATEMER TESTER FOR DISSLVED OXIGEN, CONCENTRATION, SATURATION INDEX DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

DATALOGGER PHOTO-RADIOMETER FOR SOLAR LIGHT, TEMPERATURE DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree