Battery Voltage Monitor Megger - BVM, BVM300 and BVM600

Code: Megger - BVM, BVM300 and BVM600


 

Datasheet PDF, 0.28 Mb

Description

The Megger BVM is a battery voltage measurement device that is used for the capacity testing of large, industrial battery banks commonly found in electrical power sub-stations, telecom facilities and computer data center UPS systems. When used in conjunction with a load device, such as the TORKEL unit, and test data management software, such as PowerDB and TORKEL Win, the BVM enables the user to perform a completely automated battery bank capacity test, according to IEC test method. The test also meets NERC/FERC requirements.

 

The BVM is designed in modular form where one BVM device is used for each battery or ½jar½ in the string to be tested. One BVM for each battery connects to the next in a ½daisy-chain½ fashion, thereby providing easy and economical expandability to meet the testing requirements for small-to-large battery bank systems.

 

Features:

  • Automates battery voltage measurement during capacity tests
  • ½Daisy-chain½ design allows expandability up to 120 units
  • High accuracy and stability for precise data collection
  • Integrates with TORKEL Win and PowerDB Test Data Management software
  • Wide voltage range
  • Easy set-up
 

More products MEGGER

MEGGER IDAX-300 IDAX-350 INSULATION DIAGNOSTIC ANALYZER, TAN DELTA, POWER FACTOR

• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity
• Individual temperature correction (ITC) of tan delta/power factor and oil conductivity
• 40% faster measurements with the new IDAX 5.0 SW
• Reliable measurements in high-interference environments
• Multi-function test set for transformer measurements

 

MEGGER DELTA4110 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA4000

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

DC CIRCUIT BREAKER TESTER MEGGER ½ CB360

• Capable of testing electromechanical or thermal-magnetic trip devices with dc current
• Digital timer
• High-current output up to 30,000 amperes

 

MEGGER TDR1000/3 TIME DOMAIN REFLECTOMETER & CABLE FAULT LOCATOR

• minimum resolution of 0.1 m and a 5 km maximum range
• Simple operation.
• AUTO set up for instant use.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature to allow comparison between cables.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

CURRENT SUPPLY UNIT MEGGER ½ CSU600A AND CSU600AT

• Compact and rugged
• Quick and easy to us
• Broad application range
• Excellent weight/performance ratio

 

BATTERY IMPEDANCE TESTER MEGGER - BITE2 AND BITE2P

• Determines condition of lead-acid and NiCd cells up to 7000 Ah
• On-board Pass/Warning/Fail indications
• Robust, repeatable instruments
• On-line testing

 

MICRO-OHMMETER WITH DUALGROUND SAFETY MEGGER - MJOLNER200

• Safer testing using the patented DualGroundâ„¢ technology to test circuit breakers with both sides grounded
• Fully automatic testing- microprocessor controlled
• Wide measuring range and test currents
• High powered and light

 

MEGGER TTR300 TTR310 TTR330 THREE-PHASE TRANSFORMER TURNS RATIO METER

• Stand-alone or remote-control operation
• Accurately measures ratio, phase deviation and excitation current
• Field upgradeable without compromise to calibration
• Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
• Works in the presence of high interference/high voltage
• Highest ratio measurement (45,000:1); highest accuracy (0.1%)
• Displays % error vs. name plate with pass/fail limits

 

MEGGER CARLOC CABLE LOCATION TRACING TRACE ROUTE

• Display with high contrast for good readability by day and night
• Current direction indication for clear cable identification
• Transmitter with two output signals to distinguish between cables lying side by side
• IP 65 for wet, dusty, and dirty working environments
• 100 freely adjustable transmitter frequencies (from 50 Hz to 200 kHz)

 

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing