Agilent 81150A Pulse Function Arbitrary Noise Generator 240 MHz

Code: Agilent 81150A


 

Datasheet PDF, 1.18 Mb

Description

  • 1 µHz - 120 MHz pulse generation with variable rise/fall time
  • 1 µHz - 240 MHz sine waveform output
  • 14-bit, 2 GSa/s arbitrary waveforms
  • 1 or 2 channel, coupled and uncoupled
  • 512 ksamples deep arbitrary waveform memory per channel
  • Pulse, sine, square, ramp, noise and arbitrary waveforms
  • Noise, with an adjustable crest factor, and signal repetition of 26 days
  • Differential outputs
  • FM, AM, PM, PWM, FSK modulation capabilities
  • Two selectable output amplifiers: High bandwidth or High Voltage
  • Glitch free change of timing, parameters (delay, frequency, transition time, width, duty cycle)
  • Programming language compatible with Agilent 81101A, 81104A, 81105A
  • USB, GPIB, LAN Connectivity
  • LXI Class C compliant
 

Standard accessories

  •  Certificate of calibration
  •  Local power cord
  •  USB cable
  •  Agilent automation ready CD (Agilent I/O Library, IVI-COM driver)
  •  Product CD (user guide, getting started guide)
 

Recommended options

Options:

  • Opt.001    1-channel pulse function arbitrary noise generator
  • Opt.002    2-channel pulse function arbitrary noise generator
  • Opt.1A71 ISO17025 calibration documents
  • Opt.Z54   Z540.3 calibration documents
  • Opt.PAT  License for 120 Mbit/s pattern generator
 

More products KEYSIGHT

AGILENT U2741A MODULAR USB DIGITAL MULTIMETER 5.5 DIGIT

• 5.5 digit
• 0.02% accuracy
• USB PC based Multimeter
• Make fast measurements with up to 100 readings/s

 

AGILENT 53230A RF UNIVERSAL FREQUENCY COUNTER 12 DIGIT 2 CH 350 MHZ

• 2 x 350 MHz baseband frequency
• 12 digits/sec resolution
• 6 or 15 GHz optional microwave channels
• 20 ps single-shot time resolution

 

AGILENT 34405A DIGITAL PRECISION MULTIMETER 5.5 DIGIT

• 5.5 digit
• 0.025% DC voltage accuracy
• 120,000 counts resolution

 

AGILENT 16802A PORTABLE LOGIC ANALYZER 68 CHANNELS

• 68-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

AGILENT N9310A RF SIGNAL GENERATOR 9 KHZ..3 GHZ

• 9 kHz to 3 GHz
• 0.1 Hz resolution
• 20 Hz to 80 kHz low frequency (LF) output
• -127 to +13 dBm output level range (maximum +20 dBm settable)
• Optional IQ modulator, 40 MHz bandwidth

 

DIGITAL OSCILLOSCOPE 2 X 500 MHZ AGILENT DSO7052B

• 500 MHz bandwidth
• 4 GSa/s sample rate
• 2 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

USB MODULAR DATA ACQUISITION UNIT 64-CHANNELS 250KSA/S AGILENT U2355A

• High-speed USB 2.0
• 16-bit resolution
• 64 SE/32 DI multiplex analog input channels
• Up to 250 kSa/s sampling rate
• 2 12-bit analog output channels,
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

4 X 8 DUAL MATRIX MODULE AGILENT 34931A

• Dual 4x8, 8x8, or 4x16 configurations
• 64 2-wire cross-points
• Connections to the internal DMM
• Expandable via four 2-wire analog buses

 

AGILENT E4428C ESG RF SIGNAL GENERATOR 250 KHZ..3 GHZ OR 6 GHZ

• 250 kHz to 3 GHz or 6 GHz
• 0.01 Hz resolution
• -136 to 17 dBm @ 1 GHZ and 10 dBm @ 6 GHz output power
• AM, FM, ØM, and pulse modulation

 

AGILENT N9923A FIELDFOX HANDHELD CABLE, ANTENNA, VECTOR NETWORK ANALYZER 2 MHZ..4 GHZ/ 6 GHZ

• Network Analyzer 2 MHz to 4 GHz/ 6 GHz
• Transmission/reflection (S21, S11) or full two-port (S21, S11, S12, S22)
• Cable and Antenna Analyzer 2 MHz to 4 GHz/ 6 GHz
• Power Meter 9 kHz to 24 GHz
• Vector Voltmeter 2 MHz to 4 GHz/ 6 GHz