Current Clamp Meter True-rms 1000A Agilent U1212A

Code: Agilent U1212A


 

Datasheet PDF, 0.26 Mb

Description

  • 1000 A DC and True-RMS AC current measurement
  • CAT III 1000V and CAT IV 600V safety protection
  • Small body and large jaw size up to 52mm
  • Includes full-featured DMM with resistance, capacitance, frequency, diode check, continuity
  • K-Type temperature measurements
  • Peak-hold with in-rush current measurement
  • Dual ranging mode, manual and auto
  • Large dual display
  • Manual and auto-ranging for all measurements
  • Min/max recording capability
  • One-hand operation
 

Standard accessories

  • Test leads
  • 19-mm probes
  • 4-mm probes
  • Soft carrying case
  • Quick Start Guide
  • Certi?cate of Calibration (CoC)
 

Recommended options

  • U1168A Standard Test Lead Kit
  • U1162A Alligator clips
  • U1175A Soft carrying case
  • U1186A K-type thermocouple and adapter
 

More products AGILENT

AGILENT 34411A DIGITAL PRECISION MULTIMETER 6.5 DIGIT

• 6 ½ digit resolution
• Basic accuracy: .0030 % DC,0.06% AC
• 14 measurement functions including capacitance & temperature
• 50,000 readings/sec. @ 4 1/2 digits to the PC
• 1M reading memory

 

PXI MULTIPLEXER MODULE 99-CHANNELS 100V/1A AGILENT M9103A

• 99-channel, high-density 2-wire switch multiplexer
• 100Vrms
• 1A switch/carry current
• 60W max power
• Durable 60W armature switches

 

AGILENT E4438C ESG VECTOR SIGNAL GENERATOR 250 KHZ..1 GHZ/ 2 GHZ/ 3 GHZ/ 4 GHZ/ 6 GHZ

• 250 kHz to 1 GHz, 2 GHz, 3 GHz, 4 GHz or 6 GHz
• 0.01 Hz resolution
• +17 dBm output power
• 64 MSa playback memory and 1 GSa storage
• 80 MHz dual mode internal baseband generator: arbitrary waveform and real-time I/Q

 

AGILENT 33210A FUNCTION / ARBITRARY WAVEFORM GENERATOR 10 MHZ

• 10 MHz sine and square waveforms
• Ramp, triangle, noise, and DC waveforms
• Option 002 provides 14-bit, 50 MSa/s, 8-Kpoint arbitrary waveform generation

 

AGILENT 4285A PRECISION LCR METER 75 KHZ..30 MHZ

• 75 kHz to 30 MHz in 100 Hz steps
• 0.1% Accuracy
• Measurements include |Z|-theta, |Y|-theta, R-X, G-B, C-D, Q, ESR, G, Rp, L-D, deviation, and deviation %

 

MULTIFUNCTION MODULE I/O AGILENT 34907A

• 16 bits of digital input and output
• 100 kHz totalizer input
• Two +/-12V analog outputs

 

AGILENT 81150A PULSE FUNCTION ARBITRARY NOISE GENERATOR 240 MHZ

• 1 µHz - 120 MHz pulse generation with variable rise/fall time
• 1 µHz - 240 MHz sine waveform output
• 14-bit, 2 GSa/s arbitrary waveforms
• 1 or 2 channel, coupled and uncoupled

 

AGILENT 6671A 6672A 6673A 6674A 6675A DC PROGRAMMABLE POWER SUPPLIES 2000W

• Fast, low-noise Single outputs
• Linear output regulation
• Overvoltage & overcurrent protection
• Measured V & I readback over GPIB

 

DIGITAL OSCILLOSCOPE 4 X 350 MHZ AGILENT DSOX3034A

• 350 MHz bandwidth
• 4 analog channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


AGILENT 81160A PULSE FUNCTION ARBITRARY NOISE GENERATOR 500 MHZ

• 1 µHz - 330 MHz pulse generation with variable rise/fall time
• 1 µHz - 500 MHz sine waveform output
• 14-bit, 2.5 GSa/s arbitrary waveforms
• 1 or 2 channel, coupled and uncoupled