Agilent E4980A Precision LCR Meter 20 Hz..2 MHz

Code: Agilent E4980A


 

Datasheet PDF, 0.6 Mb

Description

  • 20 Hz to 2 MHz, with 4-digit resolution in any range
  • 0.05% basic accuracy with superior measurement repeatability at low and high impedance
  • Measurement parameters: |Z|, |Y|, ?, R, X, G, B, L, C, D, Q, Rdc, Idc, Vdc
  • High-speed measurements up to 5.6 ms
  • 20 Vrms test signal
  • Built-in 40V DC Bias
  • 40 A DC support with the Agilent 42841A Bias Current Source
  • 201 points list sweep
  • GPIB, USB, LAN (LXI-C)
 

Recommended options

16034E

Test Fixture (SMD Components)

16034G

SMD Test Fixture  

16034H

SMD Array Type LCR Test Fixture  

16044A

SMD LCR Kelvin Contact Test Fixture  

16047A

Test Fixture (Axial and Radial)  

16047D

Test Fixture  

16047E

Test Fixture, 40 Hz to 110 MHz  

16048A

Test Lead, BNC Connector to BNC Connector Board  

16048D

2m BNC Test Cable  

16048E

Test Leads  

16060A

Transformer Test Fixture  

16065A

200 Vdc External Voltage Bias Fixture  

16065C

40Vdc External Voltage Bias Adapter  

16085B

Terminal Adapter  

16089A

Large Kelvin Clip Lead  

16089B

Medium Kelvin Clip Lead  

16089C

Kelvin IC Clip Lead  

16089D

Alligator Clip Lead (4 Clips)  

16089E

Kelvin Clip Leads  

16092A

Spring Clip Fixture  

16192A

Parallel Electrode SMD Test Fixture  

16194A

High Temperature Component Test Fixture

 

More products KEYSIGHT

AGILENT 81150A PULSE FUNCTION ARBITRARY NOISE GENERATOR 240 MHZ

• 1 µHz - 120 MHz pulse generation with variable rise/fall time
• 1 µHz - 240 MHz sine waveform output
• 14-bit, 2 GSa/s arbitrary waveforms
• 1 or 2 channel, coupled and uncoupled

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 250KSA/S SIMULTANEOUS AGILENT U2541A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 250 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

CURRENT CLAMP METER TRUE-RMS 1000A AGILENT U1212A

• 1000 A DC and True-RMS AC current measurement
• Small body and large jaw size up to 52mm
• Includes full-featured DMM with resistance, capacitance, frequency, diode check, continuity
• K-Type temperature measurements

 

USB MODULAR DATA ACQUISITION UNIT 16-CHANNELS 250KSA/S AGILENT U2352A

• High-speed USB 2.0
• 16-bit resolution
• 16 SE/8 DI multiplex analog input channels
• Up to 250 kSa/s sampling rate
• 24-bit programmable TTL input/output channels

 

4 X 16 DUAL MATRIX MODULE AGILENT 34932A

• Dual 4x16, 8x16, or 4x32 configurations
• 128 2-wire cross-points
• 300V, 1A switch
• 2A carry current

 

AGILENT U3401A DIGITAL PRECISION MULTIMETER 4.5 DIGIT

• 4.5 digit
• 0.02% DCV accuracy
• 50,000 counts resolution

 

DIGITAL OSCILLOSCOPE 4 X 1 GHZ AGILENT DSO7104B

• 1 GHz bandwidth
• 4 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

USB DATA ACQUISITION MAINFRAME CHASIS 3-SLOT AGILENT U2781A

• High-speed USB 2.0 (480 Mbit/s)
• Allows expansion up to 384 channels
• Hot-swappable and auto-detectable characteristic
• Internal and external 10 MHz reference clock

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 500KSA/S SIMULTANEOUS AGILENT U2542A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 500 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

AGILENT U2701A USB MODULAR OSCILLOSCOPE 2 X 100 MHZ

• 100 MHz bandwidth
• 2 channels
• 32 Mpts memory depth, 64 Mpts interleaved single-shot
• 1 GSa/s sample rate on 2 channels interleaved, 500 MSa/s each channel