Agilent E4980A Precision LCR Meter 20 Hz..2 MHz

Code: Agilent E4980A


 

Datasheet PDF, 0.6 Mb

Description

  • 20 Hz to 2 MHz, with 4-digit resolution in any range
  • 0.05% basic accuracy with superior measurement repeatability at low and high impedance
  • Measurement parameters: |Z|, |Y|, ?, R, X, G, B, L, C, D, Q, Rdc, Idc, Vdc
  • High-speed measurements up to 5.6 ms
  • 20 Vrms test signal
  • Built-in 40V DC Bias
  • 40 A DC support with the Agilent 42841A Bias Current Source
  • 201 points list sweep
  • GPIB, USB, LAN (LXI-C)
 

Recommended options

16034E

Test Fixture (SMD Components)

16034G

SMD Test Fixture  

16034H

SMD Array Type LCR Test Fixture  

16044A

SMD LCR Kelvin Contact Test Fixture  

16047A

Test Fixture (Axial and Radial)  

16047D

Test Fixture  

16047E

Test Fixture, 40 Hz to 110 MHz  

16048A

Test Lead, BNC Connector to BNC Connector Board  

16048D

2m BNC Test Cable  

16048E

Test Leads  

16060A

Transformer Test Fixture  

16065A

200 Vdc External Voltage Bias Fixture  

16065C

40Vdc External Voltage Bias Adapter  

16085B

Terminal Adapter  

16089A

Large Kelvin Clip Lead  

16089B

Medium Kelvin Clip Lead  

16089C

Kelvin IC Clip Lead  

16089D

Alligator Clip Lead (4 Clips)  

16089E

Kelvin Clip Leads  

16092A

Spring Clip Fixture  

16192A

Parallel Electrode SMD Test Fixture  

16194A

High Temperature Component Test Fixture

 

More products KEYSIGHT

DIGITAL OSCILLOSCOPE 4 X 350 MHZ AGILENT DSO7034B

• 350 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

MULTIPLEXER MODULE 70 CHANNELS AGILENT 34922A

• 70 2-wire channels
• Mix 2- or 4-wire configurations
• 100 ch/s scanning
• 300V, 1A switch
• 2A carry current
• 45 MHz Bandwidth

 

DIGITAL OSCILLOSCOPE 4 X 70 MHZ AGILENT DSOX2004A

• 70 MHz bandwidth
• 4 analog channels
• 1GSa/s per channel sample rate

 

SWITCH MODULE 64 CHANNELS AGILENT 34939A

• 64 Form A channels up to 1A, 50W
• Latching armature relays, with relay cycle counter
• Temperature sensor for overheating conditions

 

USB DATA ACQUISITION MAINFRAME CHASIS 3-SLOT AGILENT U2781A

• High-speed USB 2.0 (480 Mbit/s)
• Allows expansion up to 384 channels
• Hot-swappable and auto-detectable characteristic
• Internal and external 10 MHz reference clock

 

DIGITAL OSCILLOSCOPE 2 X 500 MHZ & LOGIC ANALYZER 16 CHANNELS AGILENT MSOX3052A

• 500 MHz bandwidth
• 2 analog channels plus 16 digital channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


DIGITAL OSCILLOSCOPE 4 X 100 MHZ AND LOGIC ANALYZER 8 CHANNELS AGILENT MSOX2014A

• 100 MHz bandwidth
• 4 analog channels plus 8 digital channels
• 1GSa/s per channel sample rate

 

AGILENT 81110A 81112A PULSE GENERATOR 330 MHZ

• 1 mHz to 330 MHz
• 1 or 2 Channels(order 2 x 81112A modules)
• 800 ps or 1.6 ns selectable
• Up to 3.8 Vpp into 50 O

 

MULTIPLEXER MODULE 40 CHANNELS AGILENT 34921A

• 40 2-wire channels
• 300V, 1A switch; 2A carry current
• 100 ch/s scanning
• Mix 2- or 4-wire configurations
• 45 MHz Bandwidth

 

HAND HELD MULTIMETER PROCESS CALIBRATOR AGILENT U1401B

• Dual display with bright LCD backlight
• 4-20 mA and 0-20 mA percentage scale readout
• 50,000 count true-RMS DMM
• Simultaneous signal source and measure