Agilent 16821A Portable Logic Analyzer 34 channels & Pattern Generator 48 channels

Code: Agilent 16821A


 

Datasheet PDF, 1.09 Mb

Description

  • 34-channel portable logic analyzer
  • 48-channel pattern generator with up to 300 MVector/s speed and 16 M vector depth

  • 4 GHz (250 ps) timing zoom with 64 K memory
  • 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
  • 500 MHz transitional timing
  • up to 250 MHz State clock rates
  • up to 250 Mb/s Data rates
  • up to 32 M acquisition memory depth
  • 15-inch (38.1 cm) color display with touch screen available(option 103)
  • Comprehensive single-ended signal support, threshold is adjustable in -5 V to 5 V (10 mV increments)
  • Automated threshold/sample position setup for accurate measurements on high-speed buses
  • Simultaneous eye diagrams on all channels identify problem signals quickly
  • Selectable memory depths: 1 M, 4 M, 16 M, 32 M
 

Recommended options

16720A-011

TTL Clock Pod and Lead Set OPT

16720A-013

Data pod and lead set, 3-state TTL/CMOS

16720A-014

TTL Data Pod and Lead Set

16720A-015

Clock pod and lead set, 2.5 volt

16720A-016

Data pod and lead set, 2.5 volt

16720A-017

Clock pod and lead set, 3.3 volt

16720A-018

Data pod and lead set, 3-state 3.3 volt

16720A-021

ECL Clock Pod and Lead Set

16720A-022

ECL Terminated Data Pod and Lead Set

16720A-023

ECL Unterminated Data Pod Lead Set

16720A-031

Clock pod and lead set, 5 volt PECL

16720A-032

Data pod and lead set, 5 volt PECL

16720A-033

Clock pod and lead set, 3.3 volt LVPECL

16720A-034

Data pod and lead set, 3.3 volt LVPECL

16720A-041

Clock pod and lead set, 1.8 volt

16720A-042

Data pod and lead set, 1.8 volt

16720A-051

LVDS Clock Pod and Lead Set

16720A-052

LVDS Data Pod and Lead Set

16800A-0B3

Service Manual

16800A-103

Front Panel with 15 inch display and touchscreen

16800A-109

External removable hard drive for 16800 series logic analyzers

16821A-001

Standard 1 M acquisition memory depth

16821A-004

Increase acquisition memory depth to 4M

16821A-016

Increase acquisition memory depth to 16M

16821A-032

Increase acquisition memory depth to 32M

16821A-A6J

ANSI Z540 Compliant Calibration

E5346A

Probe, 34 channel single-ended Mictor connector, connects to 40-pin LA cable

E5383A

Probe, 17-channel single-ended flying leads, connects to 40-pin LA cable

E5385A

Probe, 34 channel single-ended Samtec connector, connects to 40-pin LA cable

E5394A

Probe, 34 channel single-ended soft touch connectorless, connects to 40-pin LA cable

E5394A-001

Retention Module

E5396A

Probe, 17 channel single-ended soft touch connectorless, connects to 40-pin LA cable

E5396A-001

Retention Modules

E5403A

Kit of 5 retention modules for Pro Series Soft Touch Connectorless Probes

E5404A

Probe, 34 channel, soft touch pro, single-ended, connects to 40-pin LA cable

 

More products KEYSIGHT

MICROWAVE SWITCH DUAL MODULE AGILENT 34946A

• Two SPDT terminated switches
• 4 GHz, 20 GHz, or 26.6 GHz options
• High isolation, low VSWR
• Up to 50W switching

 

USB THERMOCOUPLE INPUT MODULE 31-CHANNELS AGILENT U2802A

• Up to 31 thermocouple inputs
• Configurable for thermocouple or voltage input mode independently
• Voltage input range up to 10V
• Supports thermocouple type J, K, R, S, T, N, E and B

 

AGILENT E8663D PSG RF SIGNAL GENERATOR 100 KHZ..3.2 GHZ/ 9 GHZ

• 100 kHz to 3.2 GHz or 9 GHz
• 0.001 Hz resolution
• -135 to +24 dBm typical output power with Option 1EU
• AM, FM, ØM, and pulse (may be simultaneously enabled)

 

DIGITAL OSCILLOSCOPE 4 X 350 MHZ AGILENT DSO7034B

• 350 MHz bandwidth
• 2 GSa/s sample rate
• 4 analog channels
• Standard 8 Mpts MegaZoom III deep memory

 

4 X 8 DUAL/QUAD MATRIX MODULE AGILENT 34933A

• Dual 4x8, 8x8, or 4x16 2-wire configurations
• 64 2-wire or 128 1-wire cross-points
• High-speed reed relays

 

AGILENT 33210A FUNCTION / ARBITRARY WAVEFORM GENERATOR 10 MHZ

• 10 MHz sine and square waveforms
• Ramp, triangle, noise, and DC waveforms
• Option 002 provides 14-bit, 50 MSa/s, 8-Kpoint arbitrary waveform generation

 

USB MODULAR DATA ACQUISITION UNIT 4-CHANNELS 250KSA/S SIMULTANEOUS AGILENT U2541A

• High speed USB 2.0 (480MBit/s)
• 16-bit resolution
• simultaneous analog input channels
• up to 250 kSa/s/ch
• 2 12-bit analog output channels
• 1 MSa/s analog output update rate
• 24-bit programmable TTL input/output channels

 

AGILENT N9923A FIELDFOX HANDHELD CABLE, ANTENNA, VECTOR NETWORK ANALYZER 2 MHZ..4 GHZ/ 6 GHZ

• Network Analyzer 2 MHz to 4 GHz/ 6 GHz
• Transmission/reflection (S21, S11) or full two-port (S21, S11, S12, S22)
• Cable and Antenna Analyzer 2 MHz to 4 GHz/ 6 GHz
• Power Meter 9 kHz to 24 GHz
• Vector Voltmeter 2 MHz to 4 GHz/ 6 GHz

 

MULTIPLEXER MODULE QUAD 4-CHANNELS 50 OHM AGILENT 34941A

• Quad 4-channel multiplexers
• DC to 3 GHz, 50 Ohm
• High isolation, low VSWR
• 30V, 0.5A, 10W switching
• SMA connectors

 

AGILENT E8267D PSG VECTOR SIGNAL GENERATOR 250 KHZ..20 GHZ/ 31.8 GHZ/ 44 GHZ

• 250 kHz to 20 GHz, 31.8 GHz or 44 GHz
• 0.001 Hz resolution
• +22 dBm @ 20 GHz and +18 dBm @ 40 GHz output power (typ)
• 160 MHz (extendable to 2 GHz) RF modulation bandwidth