Brand: HART SCIENTIFIC

Field Dry Well Temperature Calibrator -25°C..140°C Hart Scientific 9103

Code: Hart Scientific 9103


 

Datasheet PDF, 0.14 Mb

Description

  • -25 °C to 140 °C range
  • Lightweight and very portable
  • Accuracy to ±0.25 °C
  • ± 0.02 °C stability
  • RS-232 and Interface-it software included
  • Easy to recalibrate
 

Recommended options

9103-X 

Dry-Well (specify X, X = A, B, C, or D included insert) 

SC1-FDDW

Extended Warranty, Silver Care, Field Dry-well

3103-1 

Insert, blank 

3103-2 

Insert A 

3103-3 

Insert B 

3103-4 

Insert C 

3103-6 

Insert D 

9316 

Rugged Carrying Case

 

More products HART SCIENTIFIC

METROLOGY THERMOMETER CALIBRATION WELL -30°C..155°C HART SCIENTIFIC 9171

• -30 °C to 155 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

FIELD METROLOGY TEMPERATURE CALIBRATION WELL -25°C..150°C HART SCIENTIFIC 9142

• -25 °C to 150 °C (-13 °F to 302 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Cool to -25 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.01 °C

 

FIELD METROLOGY TEMPERATURE CALIBRATION WELL 50°C..660°C HART SCIENTIFIC 9144

• 50 °C to 660 °C (122 °F to 1220 °F) Temperature Range at 23 °C
• Lightweight, portable, and fast
• Heat to 660 °C in 15 minutes
• Built-in two-channel readout for PRT, RTD, thermocouple,
• 4-20 mA current
• True reference thermometry with accuracy to ± 0.03 °C

 

METROLOGY THERMOMETER CALIBRATION WELL 50°C..700°C HART SCIENTIFIC 9173

• 50 °C to 700 °C temperature range
• ± 0.005 °C stability
• Best-performing industrial heat sources (accuracy, stability, uniformity) in the world

 

FIELD DRY WELL TEMPERATURE CALIBRATOR 35°C..350°C HART SCIENTIFIC 9140

• 35 °C to 350 °C range
• Lightweight and very portable
• Accuracy to ±0.5 °C
• ± 0.03 °C stability

 

PRECISION INFRARED CALIBRATOR -15°C..120°C HART SCIENTIFIC 4180

• Fast, portable and easy to use
• Correct target size for most thermometers
• Calibration solutions from -15 °C to 120 °C
• Radiometrically calibrated for traceable and consistent results

 

PRECISIN REFERENCE READOUT 4-CHANNEL THERMOMETER HART SCIENTIFIC 1529 CHUB-E4

• Four channels for PRTs, thermistors, and thermocouples
• Displays eight user-selected data fields from any channel
• Logs up to 8,000 readings with date and time stamps
• Battery provides eight hours of continuous operation

 

FLUKE HART SCIENTIFIC 1594A 1595A TEMPERATURE, THERMOMETER, THERMISTOR CALIBRATOR

• Calibrate SPRTs, PRTs, RTDs and thermistors (0 O to 500 kO)
• Accuracy as good as 0.06 ppm (0.000015 °C)
• "Ratio Self-Calibration" verifies and calibrates resistance ratio accuracy
• Automatic zero-power measurements calculate thermometer probe self-heating
• Temperature-controlled internal reference resistors

 

TEMPERATURE, THERMOMETER, THERMISTOR 8-CHANNEL CALIBRATOR HART SCIENTIFIC 1560

• Reads SPRTs, RTDs, thermistors, and thermocouples
• Any configuration you like up to eight modules
• High-accuracy reference thermometer (to ±0.0013°C)
• Automates precision data acquisition

 

INFRARED THERMOMETER CALIBRATOR 50°C..500°C HART SCIENTIFIC 9132

• Certify IR pyrometers from 50 °C to 500 °C
• Large 57 mm (2.25 in) blackbody target
• RTD reference well for contact temperature measurement
• Small, compact design