Hybrid Log Periodic Broadband Antenna for EMC measurements 80 MHz..6 GHz ETS-Lindgren 3149

Code: ETS-Lindgren 3149


 

Datasheet PDF, 1.65 Mb

Description

  • Frequency Minimum     80 MHz
  • Frequency Maximum    6 GHz
  • Impedance (Nominal)   50 ?
  • Maximum Continuous Power    750 W..200 W
  • Pattern Type     directional
  • Polarization       linear
  • VSWR 6.5:1 max
  • 750 W Max Continuous Power Input
  • Meets CISPR Cross Polarization Requirements.
  • On-Axis Antenna Polarization
  • Ultra Broadband: 80 MHz -6 GHz
  • Compact Size
  • Tough Powder Coat Finish
 

More products ETS-LINDGREN

VLF MAGNETIC FIELD SURVEY METER 2..400 KHZ ETS-LINDGREN HI-3637

• 0.06 mG - 400 G (with 100X probe)
• 2 - 400 kHz
• True RMS Detection
• Three concentric orthogonal field sensors

 

RESONANT DIPOLE ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

HIGH CURRENT POWER RFI/EMI PROTECTION FILTERS IN SINGLE PHASE NETWORK 400..800A ETS-LINDGREN N2510

• >3000 Amp capability
• Fully accessible end chambers
• 80 dB Insertion Loss From 100 kHz to 10 GHz
• Excellent strength to weight ratio
• RoHS Compliant and CE Marked for Compliance with the Low Voltage Directive
• High current capability
• Compact design

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 10 KHZ..30 MHZ ETS-LINDGREN 6512

• Frequency Minimum 20 Hz
• Frequency Maximum 5 MHz
• Connectors BNC (f)
• Maximum Input Power 20 W
• Pattern Type omnidirectional
• Polarization linear

 

CONICAL LOG SPIRAL ANTENNA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

BICONICAL TRANSMITTING-RECEVING ANTENNA 20..200 MHZ ETS-LINDGREN 3104C

• Frequency Minimum 20 MHz
• Frequency Maximum 200 MHz
• Connectors Type N (f)
• FS-600 High Performance Hybrid Ferrite Tile Polyurethane Dielectric 200 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50 W
• Pattern Type omnidirectional
• Peak Power 100 W
• Polarization linear

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

ACTIVE RECEIVING LOOP ANTENNA 10 KHZ..30 MHZ ETS-LINDGREN 6502

• Frequency Minimum 10 kHz
• Frequency Maximum 30 MHz
• 1 dB Comp. Point 5 V/m
• Connectors BNC (f)
• Dynamic Range 125 dB @ 1 MHz, 85dB @ 10 kHz
• Impedance (Nominal) 50 ?
• Pattern Type omnidirectional
• Polarization linear

 

LINEAR POLARIZED LOG PERIODIC ARRAY ANTENNA 100 MHZ..1 GHZ ETS-LINDGREN 3150

• Frequency Minimum 100 MHz
• Frequency Maximum 1 GHz
• Connectors 7/8 EIA Flange (others available)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 2 kW
• Pattern Type directional
• Polarization linear

 

PASSIVEELECTRIC FIELD MONOPOLE TRANSMITTING ANTENNA 1 KHZ..30 MHZ ETS-LINDGREN 3303

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Peak Power 1 W
• Polarization linear
• Switchable Two-band Transformer
• Two Year Warranty