Horizontal/ Vertical Electric Field Generator 10 kHz..30 Mz ETS-Lindgren 5502

Code: ETS-Lindgren 5502


 

Datasheet PDF, 0.83 Mb

Description

  • Generates vertical or horizontal electric field
  • Generates Fields 200 v/m in the 10 kHz to 30 MHz Frequency Range
  • Fully Adjustable Height and Separation of Main Conductors
  • Large Immunity Volume
  • Chamber Supported

 

Electrical Specifications

Frequency

E Mode: 10 kHz - 30 MHz
H Mode: 100 kHz - 300 MHz

Input Impedance

50 ?

Max RF Input Power

10 kW

RF Connector

1-5/8" EIA

VSWR

2:1 typical

 

Applications

  • ISO-11451-2
  • SAE J551/11
  • MIL-STD 461
 

Standard accessories

  • 6 m (19.7 ft) long Conducting Elements with Retracting Wire Bundles
  • Support frame assembly
  • Motorized Winch and Pulley Assembly
  • RF Load with Ground Connections
  • RF Feed Box with Ground Connections
  • Waveguide Feed-thru Penetrations for the Chamber Ceiling
  • Ground Connection Sockets for the Chamber Floor
 

Recommended options

  • Automation of Balun Box Switches
  • Height/separation Control Connection Outside of the Chamber
  • 8 m (26.2 ft) long Elements
 

More products ETS-LINDGREN

INDUCED RF CURRENT METER 9 KHZ..70 MHZ ETS-LINDGREN HI-3702

• Wide Frequency Response (9 kHz - 70 MHz)
• Eliminates concern over foot contact and body orientation
• Monitors induced current while standing, walking, or climbing.
• Thermally based True RMS Converter Circuit for increased accuracy

 

UNIVERSAL SPHERICAL DIPOLE EMI RADIATION SOURCE ETS-LINDGREN USDS

• Portable EMI Source for Quick Test Site Characterization and Site-to-Site Comparisons
• Horizontal and Vertical Polarizations
• Selectable Pulse Mode for Testing Quasi-Peak Detectors
• 10 MHz - 10 GHz Frequency Range
• Four Switch Selectable Fundamental Frequencies: 10 MHz, 64 MHz, 100 MHz,133 MHz

 

PROTECTION FILTERS FOR TEMPEST/ RFI/ EMI DIGITAL ANALOG DATA TRANSMISSIONS ETS-LINDGREN N2460

• Suitable for EMI and Tempest Protection
• Digital and analogue transmissions
• Tubular, flat-pack or modular design

 

FIELD GENERATING PYRAMIDAL HORN ANTENNA FOR EMC AUTOMOTIVE TESTING GMW 3097 AND ES-XW7T-1A278-AC 1.2..1.4 GHZ ETS-LINDGREN 3162-01

• Frequency Minimum 1.2 GHz
• Frequency Maximum 1.4 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 550 W
• Pattern Type directional
• GMW 3097
• ES-XW7T-1A278-AC

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA FOR EMC MEASUREMENTS 400 MHZ..6 GHZ ETS-LINDGREN 3119

• Frequency Minimum 400 MHz
• Frequency Maximum 6 GHz
• VSWR Ratio (AVG) 3.5:1 max
• <2:1 above 500 MHz
• Maximum Continuous Power 1500 W @ 400 MHz, 800 W @ 6 GHz
• Peak Power 2500 W

 

RFI/ EMI CONTROL FILTERS FOR ALARM, DETECTION AND MONITORING SYSTEMS ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options

 

POWER FILTERS FOR RFI/ EMI RADIATION PROTECTION CURRENTS 6..100A ETS-LINDGREN N182X

• Current Rating 6 Amps
• Number of Lines 2
• 100dB insertion loss
• High protection rate against EMI

 

LINE IMPEDANCE STABILIZATION NETWORK ETS-LINDGREN

• Insulated Plugs for Safer Power Connections
• Coils Matched for Application
• Individually Calibrated
• One Piece, Multi-Line Design for Convenience


PASSIVEELECTRIC FIELD MONOPOLE TRANSMITTING ANTENNA 1 KHZ..30 MHZ ETS-LINDGREN 3303

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 300 W
• Peak Power 1 W
• Polarization linear
• Switchable Two-band Transformer
• Two Year Warranty

 

ELECTROMAGNETIC FIELD EMISSION METER OF ELECTRIC TRANSMISSION ELECTRIC POWER LINES ETS-LINDGREN HI-3604

• Power Line Survey Instrument
• Wide Dynamic Range
• On-Board Data Logging
• Combination E & H Readings