High Performance Power Filters for Tempest/ EMP applications currents 16..200A ETS-Lindgren N600X

Code: ETS-Lindgren N600X


 

Datasheet PDF, 0.64 Mb

Description

  • Suitable for 400Hz supplies
  • Compact Rugged Construction
  • Maximum Protection for EMP and Tempest applications
  • Current Range 16 to 200 Amperes
  • 100 dB Insertion Loss from 14 kHz to 40 GHz
  • Low power dissipation

 

APPLICATIONS

  • In high performance screened rooms and anechoic chambers the N600X series provides protection of both incoming and outgoing supplies in line with the shield performance.
  • In TEMPEST applications, the N600X filters provide an extremely high degree of protection required to obtain maximum security.
  • N600X filters are ideal for EMP applications needing to meet the most stringent NATO requirements.
  • N600X filters can be used for filtering of mains incomers entering screened room facilities.

 

Electrical Specifications

PART #

Current Max (Amps)

Voltage Max (Volts)

Frequency (Hz)

Number of Lines

Volt Drop on Full Load in a 250V 50/60 Hz System Per Line (Max)

Full Load Dissipation (W)

6000

16

250

DC/50/60/400

2

1.2

35

6001

16

440/250

DC/50/60/400

4

1

45

6002

32

250

DC/50/60/400

2

1.1

70

6003

32

440/250

DC/50/60/400

4

0.75

50

6004

63

250

DC/50/60/400

2

1.3

68

6005

63

440/250

DC/50/60/400

4

0.75

155

6006

100

250

DC/50/60/400

2

0.7

135

6007

100

440/250

DC/50/60/400

4

0.5

135

6009

200

440/250

DC/50/60/400

4

1

400

 

More products ETS-LINDGREN

HIGH CURRENT POWER PROTECTION FILTERS IN THREE PHASE NETWORK AND RFI/EMP SYSTEMS 400..800A ETS-LINDGREN N258X

• Current Rating 800 Amps
• Frequency 50/60 Hz
• Number of Lines 4
• Voltage Frequency Maximum 440/250
• Tempest Capability
• Ideal for EMPP systems

 

EMI POWER FILTERS IN TEMPEST/ EMC SYSTEM SINGLE LINE NETWORK 32..120A ETS-LINDGREN N192X

• Current Range 32 to 250 Amperes
• Very High RF Attenuation
• Fully Tested for Attenuation Performance
• Durable Construction
• CE Marked

 

DOUBLE-RIDGED WAVEGUIDE HORN ANTENNA 200 MHZ..2.5 GHZ ETS-LINDGREN 3106B

• Frequency Minimum 200 MHz
• Frequency Maximum 2.5 GHz
• Connectors Type N (f)
• Impedance (Nominal) 1600 W
• Maximum Continuous Power 800 W
• Pattern Type directional

 

CURRENT MEASUREMENT PROBES 10 KHZ..1000 MHZ ETS-LINDGREN

• 10 kHz..1000 MHz Frequency ranges
• For Standards Testing and Pre-compliance Applications
• Measures RF Current Without Direct Connection

 

FIELD GENERATING PYRAMIDAL HORN ANTENNA FOR EMC AUTOMOTIVE TESTING GMW 3097 AND ES-XW7T-1A278-AC 1.2..1.4 GHZ ETS-LINDGREN 3162-01

• Frequency Minimum 1.2 GHz
• Frequency Maximum 1.4 GHz
• Connectors Type N
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 550 W
• Pattern Type directional
• GMW 3097
• ES-XW7T-1A278-AC

 

CONICAL LOG SPIRAL ANTENNA 1..10 GHZ ETS-LINDGREN 3102

• Frequency Minimum 1 GHz
• Frequency Maximum 10 GHz
• Connectors Type N (f)
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 50 W
• Pattern Type directional
• Peak Power 100 W
• Polarization circular
• VSWR 1.6:1
• Extremely low VSWR

 

BICONICAL PRECISION MEASUREMENT ANTENNA 30..300 MHZ ETS-LINDGREN 3110C

• Frequency Minimum 30 MHz
• Frequency Maximum 300 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 250mW

 

PRECISION SLEEVE DIPOLE ANTENNA FOR RIPPLE TEST MEASUREMENT IN MOBILE COMMUNICATION & CTIA INTERNET 450..5000 MHZ ETS-LINDGREN 3126

• Range of Frequencies to Cover Wireless Device Bands: 450…5000 MHz
• Meet CTIA +/- 0.1 dB Symmetry Requirement
• Precision Gain for Range Calibration

 

BICONICAL LINEAR POLARIZED ANTENNA 30..100 MHZ ETS-LINDGREN 3159

• Frequency Minimum 30 MHz
• Frequency Maximum 100 MHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 15 kW
• Pattern Type omnidirectional
• Polarization linear

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ RFI/ EMI TEST CURRENTS 6..100A ETS-LINDGREN N255X

• Maximum protection in Tempest and EMPP applications
• Highest performing commercially available power line filter
• Over 100dB insertion loss from 10 kHz to 10 GHz
• Fully accessible end chambers
• RoHS compliant and CE marked for compliance with the low voltage directive