Sewerin BioControl 4 and 8

Code: Sewerin BioControl 4 and 8


 

Datasheet PDF, 0.35 Mb
   

Description


The premium system for professional process optimisation: economical - versatile - reliable

 

Multitec® BioControl is the professional system for continuously and automatically measuring and monitoring the volume and composition of gas. It is economical, versatile and reliable. Whether in biogas plants, landfills, sewage treatment plants or composting plants - the unique combination of a stationary unit and mobile gas measuring device enables comprehensive professional process control and optimisation.

The high-quality BioControl 4 or BioControl 8 base station offers extensive and varied measuring options. Developed specifically to meet the requirements of medium-sized to large plants, it stands for process and profit optimisation, maximum reliability and individual flexibility. This premium model is recommended for plant manufacturers with the highest technological demands.

The Multitec® BioControl system comprises the stationary fixed BioControl device and a mobile gas measuring device. Depending on individual requirements, the Multitec® 540 or Multitec® 545 is the most suitable mobile unit. Up to four or even eight measurement locations are available depending on the version (BioControl 4 or BioControl 8). This means that the operator can use any of the up to four or eight measurement locations as a fixed measuring instrument. Alternatively, the Multitec® 540 / Multitec® 545 can perform mobile measurements, e.g. directly at the fermenter, secondary fermenter or even remote units in the plant, and save the measurement values in the BioControl.

 

Advantages at a glance  

  • Professional, comprehensive and versatile measuring
  • Several motors and desulphurisers can be monitored simultaneously by at least four measuring points
  • Four analog outputs with customer-specific programming for process control (e.g. motor only starts up as of a certain methane concentration)
  • Flowmeter for determining the exact volume of biogas produced in standard cubic metres (Nm3) and calculating the motor efficiency
  • Save time and money whilst ensuring maximum safety by way of continuous automatic measurement
  • Extremely user-friendly and individual configuration
  • Process monitoring and optimisation (e.g. by substrate adjustment)
  • Successfully improve gas quality and increase yield

The BioControl 4 / BioControl 8 and Multitec® 540 / 545 combination is a unique system. Not only does it provide precise information about the gas composition, it also accurately measures and evaluates the volume of gas produced. The efficiency of a biogas plant, landfill, sewage treatment or composting plant can be exactly calculated at any time. For example, when seasonal changes occur in the substrate, you can immediately see how these affect not only the gas quality, but also the volume of gas produced.

 

More products SEWERIN

SEWERIN EX-TEC GM 4 GAS TESTER WITH ALARM FOR TOXIC GASES

• Internal data memory (PC readout possible)
• Visual and audible alarms
• Adjustable alarm thresholds
• Temperature compensated sensors
• User menu

 

SEWERIN EX-TEC HS-680 HS-660 HS-650 HS-610 EXTEC GAS ANALYZER DETECTOR

• Operated by jog dial, function keys and menu navigation
• Large matrix display with backlight
• Power supplied from four replaceable AA-size rechargeable batteries or primary batteries ½ Rapid charging in four hours
• Can also be charged without docking station

 

SEWERIN EX-TEC PM4 GAS DETECTION, GAS WARNING AND GAS CONCENTRATION MEASURING

• Large, illuminated LCD display
• Self-test on start-up
• Easy operation using three keys
• Visual and audible alarms

 

SEWERIN VARIOTEC 460 TRACERGAS

• Inspection above ground
• Inspections in houses
• Measuring in bar holes
• Gas measurement

 

SEWERIN BIOCONTROL 2

• User settings can be restored from first day of use (saved on USB stick)
• Safe, reliable measuring results thanks to self-tests during operation
• Sturdy and durable: all relevant components resistant to aggressive gases

 

SEWERIN MULTITEC 540 GAS ANALYZER

• Intuitive, menu-driven user interface with jog dial and function keys
• Large transflective display, very good readability in direct sunlight
• Selective infrared sensors for hydrocarbons and carbon dioxide
• Highly durable electrochemical sensors for oxygen and toxic gases

 

SEWERIN MULTITEC 560 GAS ANALYZER

• EC type-examination certificate: TÜV 07 ATEX 553353 X
• Measuring function: BVS 09 ATEX G 001 X, PFG 08 G 002 X (applies to ExTox warning application for CH4, CO2, O2, CO, H2S)
• Minimum eight hour battery life in use, rapid charging in four hours

 

SEWERIN MULTITEC 545 GAS ANALYZER

• Innovative operating concept with jog dial, menu navigation and function keys
• Large-format matrix display with backlight
• Selective infrared sensors for hydrocarbons and carbon dioxide
• EC sensor for hydrogen sulphide with wide measuring range (5000 ppm)

 

SEWERIN MULTITEC 410 GAS ANALYZER

• Intuitive operating concept with jog dial, menu navigation and function keys
• Large-format transflective display with backlight
• Catalytic sensor with functional safety test for nonane (C9H20)
• Rapid charging in 3 hours, even without a charging station

 

SEWERIN PORTAFID M3K PORTABLE FLAME IONISATION DETECTOR

• Automatic ignition on switch-on/manual re-ignition
• Automatic zero point setting
• Linear display from 0 - 10,000 ppm
• Adjustable alarm threshold
• Automatic alarm activation