Agilent 6060B 6063B DC Electronic Load 250-300W

Code: Agilent 6060B 6063B


 

Datasheet PDF, 0.19 Mb

Description

  • Cost-effective for single input applications
  • Convenient optional front panel input connection

 

6060B:

  • Current: 0 to 60 A
  • Volts: 3 to 60 V
  • Maximum power: 300 W
  • Ranges: 0 to 6 A, 0 to 60 A
  • Accuracy: 0.1% +/-75 mA
  • Regulation: 10 mA
  • Accuracy: 0.1% +/-50 mV
  • Regulation (w/remote sense): 10 mV
  • Ranges: 0.033 to 1 ?/ 1 to 1,000 ? / 10 to 10,000 ?
  • Accuracy: 1 O and 10 KO: 0.8% ±8 mO (with =6A at input) / 1 KO: 0.3% ±8 mS (with =6V at input)

 

6063B:

  • Current: 0 to 10 A
  • Volts: 3 to 240 V
  • Maximum power: 250 W
  • Ranges: 0 to 1 A, 0 to 10 A
  • Accuracy: 0.15% +/-10 mA
  • Regulation: 8 mA
  • Accuracy: 0.12% +/-120 mV
  • Regulation (w/remote sense): 10 mV
  • Ranges: 0.20 to 24 ?/ 24 to 10,000 ? / 240 to 50,000 ?
  • Accuracy: 24 ?: 0.8% +/-200 m? (with 1 A at input) / 10 K? and 50 K? /: 0.3% +/-0.3 mS (with 24 V at input)
 

Recommended options

  • 6060B 300W Power, 60A Current, 60V Voltage
  • 6063B 250W Power, 10 Current, 240V Voltage
 

More products KEYSIGHT

MULTIPLEXER MODULE 40/80 CHANNELS AGILENT 34923A

• 40 2-wire channels or 80 1-wire channels
• Mixed 2- or 4-wire configurations
• High-speed reed relays, with relay counter

 

AGILENT N9020A MXA SIGNAL SPECTRUM ANALYZER 20 HZ..3.6 / 8.4 / 13.6 / 26.5 GHZ

• 20 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
• 10 MHz (standard), 25 or 40 MHz (optional) analysis bandwidth
• Basic EMI precompliance measurement capability available
• Advanced analysis of more than 70 signal formats

 

AGILENT 6690A 6691A 6692A DC HIGH POWER SUPPLY 6600W

• Fast, low-noise Single outputs
• Linear output regulation
• Overvoltage & overcurrent protection
• Measured V & I readback over GPIB

 

DIGITAL OSCILLOSCOPE 4 X 70 MHZ & LOGIC ANALYZER 8 CHANNELS AGILENT MSOX2004A

• 70 MHz bandwidth
• 4 analog channels plus 8 digital channels
• 1GSa/s per channel sample rate

 

AGILENT N9000A CXA SIGNAL SPECTRUM ANALYZER 9 KHZ..3 GHZ OR 7.5 GHZ

• 9 kHz to 3.0 or 7.5 GHz Frequency range
• 10 MHz (standard), 25 MHz (optional) analysis bandwidth
• Basic EMI precompliance measurement capability available
• Standards-based PowerSuite: channel power, OBW, ACP, CCDF, SEM

 

AGILENT 4287A RF LCR METER 1 MHZ..3 GHZ

• 1 MHz to 3 GHz, with 100 kHz steps
• 1% basic accuracy
• Wide impedance measurement range from 200 milliohm to 3 kohm

 

AGILENT 81101A PULSE GENERATOR 50 MHZ

• 1 mHz to 50 MHz
• 1 Channel
• 5 ns to 200 ms variable transition time
• Up to 10 Vpp into 50 O (20 Vpp into open circuit)

 

AGILENT 81130A 81131A PULSE DATA GENERATOR 400 MHZ

• 1 kHz to 400 MHz
• 1 or 2 Channels(order 2 x 81131A modules)
• 800 ps or 1.6 ns selectable
• Up to 3.8 Vpp into 50 O

 

ACTUATOR/SWITCH MODULE 20 CHANNELS AGILENT 34903A

• 20 Channel Actuator/GP Switch
• SPDT (Form C) latching relays
• 300 V, 1 A actuation and control

 

AGILENT DSO6014L MODULAR OSCILLOSCOPE 4 X 100 MHZ

• 100 MHz bandwidth
• 4 scope channels (upgradeable to MSO with 16 digital channels)
• 2 GSa/s sample rate, 2 Mpts stand memory
• LXI class C compliant