Agilent 16803A Portable Logic Analyzer 102 channels

Code: Agilent 16803A


 

Datasheet PDF, 1.09 Mb

Description

  • 102-channel portable logic analyzer
  • 4 GHz (250 ps) timing zoom with 64 K memory
  • 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
  • 500 MHz transitional timing
  • up to 450 MHz State clock rates
  • up to 500 Mb/s Data rates
  • up to 32 M acquisition memory depth
  • 15-inch (38.1 cm) color display with touch screen available(option 103)
  • Comprehensive single-ended signal support, threshold is adjustable in -5 V to 5 V (10 mV increments)
  • Automated threshold/sample position setup for accurate measurements on high-speed buses
  • Simultaneous eye diagrams on all channels identify problem signals quickly
  • Selectable memory depths: 1 M, 4 M, 16 M, 32 M
 

Recommended options

16800A-0B3

Service Manual

16800A-103

Front Panel with 15 inch display and touchscreen

16800A-109

External removable hard drive for 16800 series logic analyzers

16803A-001

Standard 1 M acquisition memory depth

16803A-004

Increase acquisition memory depth to 4M

16803A-016

Increase acquisition memory depth to 16M

16803A-032

Increase acquisition memory depth to 32M

16803A-500

Increase maximum state speed to 500 Mb/s

16803A-A6J

ANSI Z540 Compliant Calibration

E5346A

Probe, 34 channel single-ended Mictor connector, connects to 40-pin LA cable

E5383A

Probe, 17-channel single-ended flying leads, connects to 40-pin LA cable

E5385A

Probe, 34 channel single-ended Samtec connector, connects to 40-pin LA cable

E5394A

Probe, 34 channel single-ended soft touch connectorless, connects to 40-pin LA cable

E5394A-001

Retention Module

E5396A

Probe, 17 channel single-ended soft touch connectorless, connects to 40-pin LA cable

E5396A-001

Retention Modules

E5403A

Kit of 5 retention modules for Pro Series Soft Touch Connectorless Probes

E5404A

Probe, 34 channel, soft touch pro, single-ended, connects to 40-pin LA cable

 

More products KEYSIGHT

AGILENT U2761A USB MODULAR FUNCTION GENERATOR 20 MHZ

• 20 MHz sine and square waveforms
• 14-bit, 50 MSa/s, 64 Kpoint arbitrary waveforms
• Ramp, triangle and DC waveforms

 

MULTIPLEXER MODULE 70 CHANNELS AGILENT 34922A

• 70 2-wire channels
• Mix 2- or 4-wire configurations
• 100 ch/s scanning
• 300V, 1A switch
• 2A carry current
• 45 MHz Bandwidth

 

DIGITAL OSCILLOSCOPE 4 X 200 MHZ AGILENT DSOX3024A

• 200 MHz bandwidth
• 4 analog channels
• 2 GSa/s per channel sample rate, 4 GSa/s half-channel interleaved mode


AGILENT DSO6054L MODULAR OSCILLOSCOPE 4 X 500 MHZ

• 500 MHz bandwidth
• 4 scope channels (upgradeable to MSO with 16 digital channels)
• 4 GSa/s sample rate, 8 Mpts stand memory
• LXI class C compliant

 

AGILENT U2702A USB MODULAR OSCILLOSCOPE 2 X 200 MHZ

• 200 MHz bandwidth
• 2 channels
• 32 Mpts memory depth, 64 Mpts interleaved single-shot
• 1 GSa/s sample rate on 2 channels interleaved, 500 MSa/s each channel


PXI MICROWAVE SWITCH MODULE DC-26.5GHZ AGILENT M9156C

• Hybrid Dual Transfer Switch
• Broadband from DC to 26.5 GHz
• Unmatched isolation 92 dB at 8 GHz
• Long life cycles - 5 million cycles guaranteed, 10 million cycles typical

 

AGILENT N5230C PNA-L MICROWAVE NETWORK ANALYZER 300 KHZ..6/ 13.5/ 20/ 40/ 50 GHZ

• 300 kHz to 6 GHz, 2-port
• 300 kHz to 13.5 GHz, available in 2- and 4-port
• 10 MHz to 20 GHz, available in 2- and 4-port
• 10 MHz to 40 GHz, 2-port
• 10 MHz to 50 GHz, 2-port

 

CURRENT CLAMP METER TRUE-RMS 1000A AGILENT U1211A

• 1000 A True-RMS AC current measurement
• Small body and large jaw size up to 52mm
• Includes full-featured DMM with resistance, capacitance, frequency, diode check, continuity

 

AGILENT 16803A PORTABLE LOGIC ANALYZER 102 CHANNELS

• 102-channel portable logic analyzer
• 4 GHz (250 ps) timing zoom with 64 K memory
• 1.0 GHz / 500 MHz (half / full-channel) conventional timing with deep memory
• up to 450 MHz State clock rates
• up to 500 Mb/s Data rates
• up to 32 M acquisition memory depth

 

AGILENT N9020A MXA SIGNAL SPECTRUM ANALYZER 20 HZ..3.6 / 8.4 / 13.6 / 26.5 GHZ

• 20 Hz to 3.6, 8.4, 13.6, or 26.5 GHz
• 10 MHz (standard), 25 or 40 MHz (optional) analysis bandwidth
• Basic EMI precompliance measurement capability available
• Advanced analysis of more than 70 signal formats