Resonant Dipole Antenna 30 MHz..1 GHz ETS-Lindgren 3121D

Code: ETS-Lindgren 3121D


 

Datasheet PDF, 0.47 Mb

Description

  • Frequency Minimum     30 MHz
  • Frequency Maximum    1 GHz
  • Impedance (Nominal)   50 ?
  • Maximum Continuous Power    50W-260W
  • Pattern Type     omnidirectional
  • Polarization       linear
  • VSWR <1.6:1
  • FCC Design
  • Low VSWR and Balun Loss
  • Individually Calibrated
  • Appropriate for site attenuation measurements
  • Both Stinger and EMCO Mounts Included
 
 

Model

Frequency

Connectors

Maximum Continuous Power

Balun 1

30 MHz - 60 MHz

Type N (f)

260 W

Balun 2

60 MHz - 140 MHz

Type N (f)

160 W

Balun 3

140 MHz - 400 MHz

Type N (f)

80 W

Balun 4

400 MHz - 1 GHz

Type N (f)

50 W

 

More products ETS-LINDGREN

RFI/ EMI CONTROL FILTERS FOR ALARM, DETECTION AND MONITORING SYSTEMS ETS-LINDGREN N296X/ N2972

• Tubular, flat-pack or modular design
• Attenuation from 100dB at 10kHz
• Suitable for EMI, EMP and Tempest protection
• 24V DC and 250V AC/DC options

 

HIGH PERFORMANCE POWER FILTERS FOR TEMPEST/ EMI/ EMC TEST CURRENTS 16..200A ETS-LINDGREN N500X

• Low power dissipation
• Compact Rugged Construction
• 100dB insertion loss from 40kHz
• Suitable for 400Hz supplies
• Current Range 16 to 200 Amperes

 

QUAD-RIDGED OPEN BOUNDARY HORN ANTENNA 400 MHZ..10 GHZ ETS-LINDGREN 3164-10

• Frequency Minimum 400 MHz
• Frequency Maximum 10 GHz
• VSWR Ratio (AVG) 5:1 maximum, 1.75:1 average
• Maximum Continuous Power 100 watts @ 400 MHz, 20 watts @ 10 GHz
• Impedance (Nominal) 50 ?

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5405

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

E-FIELD ELECTROMAGNETIC MEASUREMENT USB/ RS232 INTERFACES FOR PC ETS-LINDGREN

• USB & RS232 Interface Modules available for Record & View measurements
• Electric Field Probes for 10 kHz..40 GHz frequencies

 

RESONANT DIPOLE ANTENNA 30 MHZ..1 GHZ ETS-LINDGREN 3121D

• Frequency Minimum 30 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 ?
• Maximum Continuous Power 50W-260W
• Pattern Type omnidirectional
• Polarization linear

 

GTEM TEST CELL FOR EMC RADIATED EMISSIONS & IMMUNITY ETS-LINDGREN 5407

• Frequency: DC - 20 GHz (RI) 2 9 kHz - 5 GHz (RE) 1
• Post Production
• For all Phases of EMC Testing - Design Qualification - Pre-Compliance
• Full Compliance IEC 61000-4-3 ANSI C63.4

 

CONICAL LOG SPIRAL ANTENNA 200 MHZ..1 GHZ ETS-LINDGREN 3101

• Frequency Minimum 200 MHz
• Frequency Maximum 1 GHz
• Impedance (Nominal) 50 Ohm
• Maximum Continuous Power 100 W
• Pattern Type directional
• Peak Power 150 W
• Polarization circular
• VSWR 2.4:1
• Extremely low VSWR
• Individually calibrated

 

BULK INJECTION CURRENT PROBES 10 KHZ..400 MHZ ETS-LINDGREN 95236-1/ 95242-1

• 95236-1: frequency range is 10 kHz to 100 MHz
• 95242-1: frequency range is 2 MHz to 400 MHz
• Maximum Power: 100W

 

PASIVE LOOP SHIELDED ANTENNA FOR SHIELDING AND IMMUNITY TESTING 1 KHZ..30 MHZ ETS-LINDGREN 6509

• Frequency Minimum 1 kHz
• Frequency Maximum 30 MHz
• Connectors Type N (f)
• Impedance (Nominal) 50 ?
• Maximum Input Power 1 kW
• Pattern Type omnidirectional
• Polarization linear