Cod: E Instruments E8500
Descriere
E8500 is the most powerful and advanced portable gas analyzer on the market, and is a complete, portable tool for EPA compliance-level emissions monitoring.
Table A - Electrochemical Sensors
O O2 Sensor (0 - 25 %)
C CO Sensor (0 - 8000 ppm) with Dilution Auto-Range up to 20,000 ppm
N NO Sensor (0 - 4000 ppm) D NO2 Sensor (0 - 1000 ppm) S SO2 Sensor (0 - 4000 ppm) H H2S Sensor (0 - 500 ppm)
Table B - NDIR (non-dispersive infrared) Sensors
ABC CO2 Sensor (0 - 20 %), CxHy Sensor (0 - 3 %), and High CO Sensor (0 - 15 %)
0 No NDIR sensors
Table C - Sampling Probes and Hoses
12 12" (300mm) Probe, 1470F (800C) max, with 10’ (3m) Dual Hose
30 30" (750mm) Probe, 1470F (800C) max, with 10’ (3m) Dual Hose
40HT 40" (1m) Probe, 2190F (1200C) max, with 10’ (3m) Hose for High Temperature Combustion Applications
60HT 60" (1.5m) Probe, 2190F (1200C) max, with 10’ (3m) Hose for High Temperature Combustion Applications
Accesorii standard
Standard E8500 Configuration (E8500-OCN-0-12) Includes the following:
- O2, CO, and NO gas sensors
- Thermoelectric chiller with automatic condensate drain pump
- Rechargeable battery pack
- 110-240VAC/50-60Hz battery charger
- 12"/300mm probe with 10’/3m dual hose
- Stack gas & air temperature measurements
- Draft & differential pressure measurements
- Calculated values for efficiency, excess air, & CO2%
- Internal memory (1000 tests)
- Real-time software package with Bluetooth module
- Wireless Bluetooth communications
- Protective carrying case
- Calibration certificate
- Operations manual
Optiuni recomandate
|
|
||||
|
Maximum Number of Sensors |
2 |
4 |
5 |
9 |
|
Internal Memory (Samples Stored) |
900 |
900 |
1000 |
1000 |
|
Draft/Differential Pressure |
Standard |
Standard |
Standard |
Standard |
|
Gas Velocity |
|
Optional |
Optional |
Optional |
|
Built-In Printer (Non-Thermal) |
Standard |
Standard |
Optional Remote Wireless Printer |
Optional Remote Wireless Printer |
|
| ||||
|
O2 Sensor (0-25%) |
Standard |
Standard |
Standard |
Standard |
|
CO Sensor (0-8000ppm) |
Standard |
Standard |
Standard |
Standard |
|
CO Dilution Auto-Range (automatic) |
|
Standard, up to 50,000ppm |
Standard, up to 20,000ppm |
Standard, up to 20,000ppm |
|
CO2 Calculated (0-99.9%) |
Standard |
Standard |
Standard |
Standard |
|
| ||||
|
NO Sensor (0-4000ppm) |
|
Standard |
Standard |
Standard |
|
NO2 Sensor (0-1000ppm) |
|
Optional |
Optional |
Optional |
|
SO2 Sensor (0-4000ppm) |
|
Optional |
Optional |
Optional |
|
CxHy Sensor Pellistor type (0-5%) |
|
Optional |
|
|
|
H2S Sensor (0-500ppm) |
|
|
|
Optional |
|
| ||||
|
CO2 NDIR Sensor (0-20%) |
|
|
|
Optional |
|
CxHy NDIR Sensor (0-3%) |
|
|
|
Optional |
|
CO NDIR Sensor (0-15%) |
|
|
|
Optional |
|
| ||||
|
Built-In Peltier Chiller |
|
|
|
Standard |
|
Bluetooth Wireless Communications |
Standard |
Standard |
Standard |
Standard |
|
Software Package |
Standard |
Standard |
Standard, Real-Time |
Standard, Real-Time |
|
|
||||
Alte produse E-INSTRUMENTS
|
ANALIZOR DE GAZ NOXE O2 CO NO NO2 SO2 MASURAREA EMISIILOR LA COSURI E5500
• Up to 5 Gas Sensors: O2, CO, NO, NO2, SO2 (Electrochemical) |
|
ANALIZOR DE GAZE INDUSTRIALE EMISII COMBUSTIE E8500
• Up to 9 Gas Sensors: O2, CO, NO, NO2, SO2, H2S (Electrochemical), CO2, CxHy, High CO (NDIR) |
|
5 IN 1: ANALIZOR GAZE COMBUSTIE SI SCURGERI MONOXID DE CARBON BTU1100
• 5 Tools Built-In ONE: |
|
ANALIZOR GAZE COMBUSTIE MONITORIZARE INSTALATII HVAC SI MENTENANTA INDUSTRIALA BTU4400
• Up to Four Gas Sensors: O2, CO, NO, & NO2 OR O2, CO, NO, & SO2 |
|
6 IN 1: ANALIZOR GAZE COMBUSTIE O2 CO2 CO NO NOX BTU900
• 6 Tools Built-In ONE: |
|
ANALIZOR PORTABIL GAZE INDUSTRIALE ARSE EMISII SI COMBUSTIE E4400
• Up to Four Gas Sensors: O2, CO, NO, NO2, SO2, CxHy |
|
ANALIZOR PORTABIL DE GAZE INDUSTRIALE MENTENANTA EMISII SI PROCESE DE COMBUSTIE E1100
• O2 and CO Gas Sensors |
|
DETECTOR PORTABIL SCURGERI GAZE COMBUSTIBIL METAN GPL 7899
• Visual LED screen & Audible Alarms |