Brand: Applied Precision

Transformator curent rejector mod comun testare contoare electricitate Applied Precision CMRI

Cod: Applied Precision CMRI


 

Brosura produs PDF, 0.16 Mb
   

Descriere

Precision Electronically Compensated Current Transformer

 
Common Mode Rejecter for testing meters with interconnected current and voltage circuits - with Remote Load Management
 

The Precision Electronically Compensated Current Transformer CMR-I is a small-sized electronically compensated current transformer unit for isolated precision current transmission. The through-hole concept and single wire capability enable any user defined current ratio. The unit is dedicated for testing of electricity meters with closed current-potential circuits and for universal step-up/down current transformation applications with excellent accuracy and dynamics.

The CMR-I 2x30 is equipped with Load Monitoring, Protection Circuits and Load Bypass via serial remote control.

The CMR-I can be implemented into any existing test system with negligible additional power losses. Current ratio can be set by number of primary and secondary wires passing the hole. The internal electronics of the device assures the specified accuracy for any up/down ratio.

 

 

  • Standalone through-hole precision electronically compensated transformer with single
  • wire capability
  • Excellent accuracy and dynamics
  • Remote control via serial communication
  • Monitoring of individual contact resistance and power loss
  • Protection against open circuit and overload
  • Programmable load by-pass
  • Automatic unused position by-pass
  • Easy implementation to existing systems
  • Simple user test of functionality and accuracy
  • Accuracy maintained for any up or down current transformation

 

Models:

 

Model

Phases

Class

 

 

 

CMR-I 2130S

1

0.01

CMR-I 2130E

1

0.02

CMR-I 2130A

1

0.05

 

 

 

CMR-I 2230S

2

0.01

CMR-I 2230E

2

0.02

CMR-I 2230A

2

0.05

 

 

 

CMR-I 2330S

3

0.01

CMR-I 2330E

3

0.02

CMR-I 2330A

3

0.05

 

Alte produse APPLIED PRECISION

STAND AUTOMATIZAT MASURA, TESTARE, CALIBRARE CONTOARE ELECTRICITATE APPLIED PRECISION ELMA

• The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals.
• The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content.

 

UNITATE EVALUARE LOCALA EROARE CONTOARE ELECTRICITATE TESTATE APPLIED PRECISION OPS

• Remotely configurable either for reflexive mark or SO output of electromechanical or LED of electronic meters
• Supplied with enhanced optical scanner working with coded signal which suppresses false light signals
• Auto-calibration capability significantly increases the work comfort and productivity of the test system
• Remotely controlled internal dividers enable evaluation of high constant meters with light impulses up to 1 kHz

 

SOFTWARE GESTIONARE DATE SISTEME AUTOMATE MASURA SI TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION ELMA

• User friendly programs for Microsoft Windows.
• Optional network support in distributed systems : client / server communication with central database via any type of computer network.
• Multilingual user interface with predefined and user definable dictionaries enables immediate national and regional implementation.
• Simple switch of display format from global characteristics of the process to detailed results on any meter.

 

TRANSFORMATOR CURENT REJECTOR MOD COMUN TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION CMRI

• Standalone through-hole precision electronically compensated transformer with single
• wire capability
• Excellent accuracy and dynamics
• Remote control via serial communication
• Monitoring of individual contact resistance and power loss
• Protection against open circuit and overload

 

SURSA TRIFAZATA SARCINA FANTOMA CU CONTOR ETALON INTEGRAT PT CALIBRARE CONTOARE ELECTRICE

• Multifunction portable signal source with integrated working standard of power and energy
• Model PTE 2100A : 1-phase, 0.05% Class Accuracy
• Model PTE 2100E : 1-phase, 0.02% Class Accuracy
• Model PTE 2300A :3-phase, 0.05% Class Accuracy
• Model PTE 2300E : 3-phase, 0.02% Class Accuracy
• Power Source per phase: Voltage 3..300V, Current 1mA..120A
• Reference Meter per phase : Voltage 30..300V, Current 1mA..120A

 

CONTOR ETALON PORTABIL ELECTRICITATE APPLIED PRECISION WS

• Lightweight compact size
• Single-phase and three-phase versions, accuracy classes 0.2, 0.1, 0.05
• USB, RS-232 and optical interface
• Vector diagram and signal shape display (oscilloscope mode)
• Harmonics analysis in tabular and graphical format
• Two universal input channels for any combination of Voltage and Current probes for Power or CT / VT ratio
• Optional wireless communication interface and wireless scanning head
• Optional portable printer

 

SONDE DE CURENT AC FLEXIBILE ROGOWSKI APPLIED PRECISION SYMMPROFLEX

• Accuracy up to 0.2 % in amplitude and 0.1 ° in phase
• No additional error for wire position
• Symmetric flexible shielding pp for excellent suppression of strange electric fields
• Symmetric sensor coil pp for excellent suppression of strange magnetic fields
• Low noise, dual gain, high CMRR amplifier with precision integrator pp
• Two sensor cable versions: high voltage Ø 12.6 mm and super flexible Ø 6 mm

 

TRANSFORMATOR DE TENSIUNE SI PRECIZIE CU REJECTIE MOD COMUN TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION CMR-U 1110A

• DIN rail mounting possibility
• Accuracy class 0.05
• Elimination of residual capacitive current from the input to output
• Operation without external power supply
• Unity transfer ratio of the CMR-U unit enables simple user test of functionality and accuracy
• Built-in short circuit, overload and misconnection protection

 

STANDARD REFERINTA FAZA ZERO APPLIED PRECISION ZPS 1101

• Broad-band operation up to 100th harmonic of mains frequency
• Optional scalable current up to 240 A (720 A)
• nominally zero phase angle between the current flowing through the resistor and the respective voltage on its voltage terminals

 

SURSA TENSIUNE SI CURENT DE INALTA PUTERE SI PRECIZIE CALIBRAT CONTOARE APPLIED PRECISION PS

• 1 or 3 Phases
• 0.2 0.05 0.02 0.01 Class
• 100 VA to 2500 VA Output Power
• Up to 500 V Output Voltage
• Up to 200 A Output Current
• Modular design with simple customization
• Signal generation based on digital synthesis of the signal waveform