Brand: Applied Precision

Standard referinta clasa 0.05 0.02 0.01 calibrare contoare electrice Applied Precision RS 2x30

Cod: Applied Precision RS 2x30


 

Brosura produs PDF, 0.5 Mb
             

Descriere

  • Single-phase and three-phase versions in classes 0.05, 0.02, 0.01
  • Current measurement up to 120, 160, 200 A or with optional Current Extender up to 240 A
  • Continuous voltage and current ranges with auto-range functionality
  • Independent input channels (three fully independent differential voltage input circuits in three-phase version)
  • Four independent fully programmable impulse outputs assignable to various quantities or constant frequency
  • Direct meter testing possibility (with supplied accessories)
  • Portable with special transport case
  • Rack mountable with 2U form factor
  • Programmable meter constant
  • Precision 24-bit A/D conversion
  • Digital signal processing

 

Description

 

The Reference Standard RS 2x30 is a single-phase (RS 2130) and three-phase (RS 2330) precision meter for electrical

power and energy measurement. The Reference Standard is designed to meet all requirements put on a reference standard in a single- and three-phase electricity meter testing and calibration systems. The Reference Standard can be set to any real or artificial mode of operation in three phase system and is capable to evaluate the individual quantities per phase and the three-phase cumulative quantities as well.

Reference Standard is based on precision 24-bit A/D conversion and digital signal processing technology enabling accurate evaluation of all main and informative quantities. Beyond measurement of all kinds of power, voltage, current and phase, the meter measures the harmonic content and distortion of the input signals.

The meter constant of Reference Standard generating value-proportional impulses on the four frequency outputs is freely programmable. This unique feature along with the extremely high maximum output frequency exceeding 2 MHz allows precision error evaluation of tested meters even at shortest integration period. All four freely programmable independent impulse outputs can be assigned to various quantities which for example enable to triple the testing capacity of the threephase test system when testing single-phase meters.

Any of impulse outputs can be set to generate any precise constant frequency for testing purposes.

 

The Reference Standard RS 2330 is equipped with three fully independent differential voltage input circuits. Therefore the meter can be configured to evaluate signals on three independent channels. This feature in combination with possibility to assign the impulse outputs to any combination of the input channels enables to use the device for example in single-phase system with one channel as reference while the free channels can monitor additional information like power consumption of the current and voltage circuits or contact error in the test circuit.
 
 

Models

 

Model

Phases

Class

Max. Current

RS 2330A /5A

3

0.05

5 A

RS 2330A

3

0.05

120 A

RS 2330A /160A

3

0.05

160 A

RS 2330A /200A

3

0.05

200 A

RS 2330E /5A

3

0.02

5 A

RS 2330E

3

0.02

120 A

RS 2330E /160A

3

0.02

160 A

RS 2330E /200A

3

0.02

200 A

RS 2330S /5A

3

0.01

5 A

RS 2330S

3

0.01

120 A

RS 2330S /160A

3

0.01

160 A

RS 2330S /200A

3

0.01

200 A

 

 

Model

Phases

Class

Max. Current

RS 2130A /5A

1

0.05

5 A

RS 2130A

1

0.05

120 A

RS 2130A /160A

1

0.05

160 A

RS 2130A /200A

1

0.05

200 A

RS 2130E /5A

1

0.02

5 A

RS 2130E

1

0.02

120 A

RS 2130E /160A

1

0.02

160 A

RS 2130E /200A

1

0.02

200 A

RS 2130S /5A

1

0.01

5 A

RS 2130S

1

0.01

120 A

RS 2130S /160A

1

0.01

160 A

RS 2130S /200A

1

0.01

200 A

 

Accesorii standard

Code

Description

RS 2130A

RS 2330A

RS 2130E

RS 2330E

RS 2130S

RS 2330S

RSCS 1100

Single Phase Cable Set

s

-

s

-

s

-

RSCS 1300

Three Phase Cable Set

-

s

-

s

-

s

OPS

Error Calculator (Local Evaluation Unit OPS)

s

s

s

s

s

s

OPTS 2100

Optical Sensor

s

s

s

s

s

s

OPFC 1000

Fixing Clamp for Optical Sensor

s

s

s

s

s

s

ED 1000

External Divider

o

o

s

s

s

s

RSTC 1000

Transport Case

o

o

s

s

s

s

CE 1124B

Single Phase Current Extender  240 / 5 A, class 0.005

o

-

o

-

o

-

CE 1324B

Three Phase Current Extender  240 / 5 A, class 0.005

-

o

-

o

-

o

 
s … standard *

o … optional

- … not available

 

* Standard accessories defined for devices sold apart of Power Source

 

Alte produse APPLIED PRECISION

STAND AUTOMATIZAT MASURA, TESTARE, CALIBRARE CONTOARE ELECTRICITATE APPLIED PRECISION ELMA

• The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals.
• The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content.

 

RECTIFICATOR UNDA CURENT DIRECT TESTARE CONTOARE ELECTRCITATE APPLIED PRECISION HWR

• Ideal zero-voltage switch
• Negligible power loss
• Simple functionality modification

 

SURSA TENSIUNE SI CURENT DE INALTA PUTERE SI PRECIZIE CALIBRAT CONTOARE APPLIED PRECISION PS

• 1 or 3 Phases
• 0.2 0.05 0.02 0.01 Class
• 100 VA to 2500 VA Output Power
• Up to 500 V Output Voltage
• Up to 200 A Output Current
• Modular design with simple customization
• Signal generation based on digital synthesis of the signal waveform

 

ANALIZOR PORTABIL PROPRIETATI TRANSFER CALDURA APPLIED PRECISION ISOMET 2114

• Measurement of Thermal Conductivity, Thermal Diffusivity, Volume Heat Capacity and Temperature
• Lightweight compact size
• Color graphic display and alphanumerical keypad
• USB and RS-232 interface
• High capacity internal memory for results
• Transport case with high protection degree

 

TRANSFORMATOR DE TENSIUNE SI PRECIZIE CU REJECTIE MOD COMUN TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION CMR-U 1110A

• DIN rail mounting possibility
• Accuracy class 0.05
• Elimination of residual capacitive current from the input to output
• Operation without external power supply
• Unity transfer ratio of the CMR-U unit enables simple user test of functionality and accuracy
• Built-in short circuit, overload and misconnection protection

 

TRANSFORMATOR CURENT REJECTOR MOD COMUN TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION CMRI

• Standalone through-hole precision electronically compensated transformer with single
• wire capability
• Excellent accuracy and dynamics
• Remote control via serial communication
• Monitoring of individual contact resistance and power loss
• Protection against open circuit and overload

 

CONTOR ETALON PORTABIL ELECTRICITATE APPLIED PRECISION WS

• Lightweight compact size
• Single-phase and three-phase versions, accuracy classes 0.2, 0.1, 0.05
• USB, RS-232 and optical interface
• Vector diagram and signal shape display (oscilloscope mode)
• Harmonics analysis in tabular and graphical format
• Two universal input channels for any combination of Voltage and Current probes for Power or CT / VT ratio
• Optional wireless communication interface and wireless scanning head
• Optional portable printer

 

UNITATE EVALUARE LOCALA EROARE CONTOARE ELECTRICITATE TESTATE APPLIED PRECISION OPS

• Remotely configurable either for reflexive mark or SO output of electromechanical or LED of electronic meters
• Supplied with enhanced optical scanner working with coded signal which suppresses false light signals
• Auto-calibration capability significantly increases the work comfort and productivity of the test system
• Remotely controlled internal dividers enable evaluation of high constant meters with light impulses up to 1 kHz

 

CONTOR ETALON DE PRECIZIE CLASA 0.1 APPLIED PRECISION XX20

• Class 0.1
• Precision 24-bit A/D conversion and digital signal processing
• Continuous voltage and current ranges with auto-range functionality
• Direct meter testing possibility (with supplied accessories)
• Rack mountable with 2U form factor
• Current measurement up to 120 A
• Programmable meter constant

 

STANDARD REFERINTA FAZA ZERO APPLIED PRECISION ZPS 1101

• Broad-band operation up to 100th harmonic of mains frequency
• Optional scalable current up to 240 A (720 A)
• nominally zero phase angle between the current flowing through the resistor and the respective voltage on its voltage terminals