Half Wave Rectifier

 

Direct current and even harmonics test unit

 

Half Wave Rectifier is designed for meter testing according to IEC 62053-21 Appendix A.1 - Half wave rectification (d. c. and even harmonics).

The Half Wave Rectifier HWR 1x12B is a single phase (HWR 1112B) and three phase (HWR 1312B) device which acts as an ideal diode with null-voltage switch and negligible power loss. The device enables to test single or three-phase meters up to 120A. It requires division of tested meters into two equal sections. The sections are fed by the opposite half-wave. Due to null-voltage switch principle the symmetry of the load impedance is not critical for exact power split and therefore for the measurement accuracy. The Half Wave Rectifier acts as a linear device and does not affect the current source signal distortion.

 

 

Half Wave Rectifier has two modes of operation:

Half Wave mode

The input current is split - the negative half wave flows through the Section 1 and the positive half wave flows through the Section 2

Normal mode (Half Wave Disabled)

Both sections are connected in series and the input current flows through both sections

 

 

  • Ideal zero-voltage switch
  • Negligible power loss
  • Simple functionality modification

 

Models

 

Model

Phases

HWR 1112B

1

HWR 1312B

3

 

Alte produse APPLIED PRECISION

STANDARD REFERINTA FAZA ZERO APPLIED PRECISION ZPS 1101

• Broad-band operation up to 100th harmonic of mains frequency
• Optional scalable current up to 240 A (720 A)
• nominally zero phase angle between the current flowing through the resistor and the respective voltage on its voltage terminals

 

RECTIFICATOR UNDA CURENT DIRECT TESTARE CONTOARE ELECTRCITATE APPLIED PRECISION HWR

• Ideal zero-voltage switch
• Negligible power loss
• Simple functionality modification

 

STANDARD REFERINTA CLASA 0.05 0.02 0.01 CALIBRARE CONTOARE ELECTRICE APPLIED PRECISION RS 2X30

• Single-phase and three-phase versions in classes 0.05, 0.02, 0.01
• Current measurement up to 120, 160, 200 A or with optional Current Extender up to 240 A
• Continuous voltage and current ranges with auto-range functionality
• Independent input channels (three fully independent differential voltage input circuits in three-phase version)
• Four independent fully programmable impulse outputs assignable to various quantities or constant frequency
• Direct meter testing possibility (with supplied accessories)
• Portable with special transport case

 

SURSA TRIFAZATA SARCINA FANTOMA CU CONTOR ETALON INTEGRAT PT CALIBRARE CONTOARE ELECTRICE

• Multifunction portable signal source with integrated working standard of power and energy
• Model PTE 2100A : 1-phase, 0.05% Class Accuracy
• Model PTE 2100E : 1-phase, 0.02% Class Accuracy
• Model PTE 2300A :3-phase, 0.05% Class Accuracy
• Model PTE 2300E : 3-phase, 0.02% Class Accuracy
• Power Source per phase: Voltage 3..300V, Current 1mA..120A
• Reference Meter per phase : Voltage 30..300V, Current 1mA..120A

 

SONDE DE CURENT AC FLEXIBILE ROGOWSKI APPLIED PRECISION SYMMPROFLEX

• Accuracy up to 0.2 % in amplitude and 0.1 ° in phase
• No additional error for wire position
• Symmetric flexible shielding pp for excellent suppression of strange electric fields
• Symmetric sensor coil pp for excellent suppression of strange magnetic fields
• Low noise, dual gain, high CMRR amplifier with precision integrator pp
• Two sensor cable versions: high voltage Ø 12.6 mm and super flexible Ø 6 mm

 

TRANSFORMATOR DE PRECIZIE TENSIUNE SECUNDAR IZOLAT MONOFAZAT APPLIED PRECISION D-MSVT 1110B

• DIN rail mounting possibility
• Accuracy class 0.05 for differential measurement
• Optimized for minimum residual capacitive current from the input to output circuits
• Operation without external power supply
• Selectable 1:1, 1:2, 1:0.5 transfer ratio
• Built-in short circuit protection

 

TRANSFORMATOR CURENT REJECTOR MOD COMUN TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION CMRI

• Standalone through-hole precision electronically compensated transformer with single
• wire capability
• Excellent accuracy and dynamics
• Remote control via serial communication
• Monitoring of individual contact resistance and power loss
• Protection against open circuit and overload

 

ANALIZOR PORTABIL PROPRIETATI TRANSFER CALDURA APPLIED PRECISION ISOMET 2114

• Measurement of Thermal Conductivity, Thermal Diffusivity, Volume Heat Capacity and Temperature
• Lightweight compact size
• Color graphic display and alphanumerical keypad
• USB and RS-232 interface
• High capacity internal memory for results
• Transport case with high protection degree

 

STAND AUTOMATIZAT MASURA, TESTARE, CALIBRARE CONTOARE ELECTRICITATE APPLIED PRECISION ELMA

• The accuracy of the power and energy reference meter is available up to 0.01 %. The reference meter measures all main and influencing quantities inclusive harmonic analysis and distortion of the test signals.
• The available power and the maximum current of 240 A of extremely pure synthesized 4-quadrant test signal covers the needs of both precision and high capacity testing laboratories. The test signal can be created with user defined harmonic content.

 

SOFTWARE GESTIONARE DATE SISTEME AUTOMATE MASURA SI TESTARE CONTOARE ELECTRICITATE APPLIED PRECISION ELMA

• User friendly programs for Microsoft Windows.
• Optional network support in distributed systems : client / server communication with central database via any type of computer network.
• Multilingual user interface with predefined and user definable dictionaries enables immediate national and regional implementation.
• Simple switch of display format from global characteristics of the process to detailed results on any meter.