Politici de confidentialitate
• From DC to 10 kHz AC fields (TRUE RMS)• Automatic probe detection• Display in Gauss, Tesla, Oersted or A / m• Bargraph visualization• Hand-held device for determining magnetic field strength• High accuracy of 0,5 % and repeatability• Data transfer to PC via USB• Multicolour touch TFT 320 x 240 px
• Digital precision Gaussmeter for determining the magnetic field strength of permanent magnets and systems• High accuracy of ± 0.05 %• DC, AC to 30 kHz (True RMS)• Multicolour touch TFT 800 x 480 px• Relative, Auto Zero, Data storage,• Data transfer to PC via USB
• Single-channel Gaussmeter with a resolution of 4 ¾ digits • measuring accuracy of ± 0.20 % of the measured value• readings on a 2-line LCD display with background light• Measuring range: 350 mG, 3.5 G, 35 G, 350 G, 3.5 kG, 35 kG, 350 kG• Measuring frequency: DC, AC up to 10 kHz• USB Interface
• Precision laboratory Gaussmeter for determining the magnetic field strength of permanent magnets and systems• Measurement of magnetizing pulses up to 20 kHz• User-friendly measuring instrument• Single-channel Gaussmeter with a resolution of 5 3/4 digits • measuring accuracy of ± 0,075 % of the measured value• Measuring range: 35 mG, 350 mG, 3.5 G, 35 G, 350 G, 3.5 kG, 35 kG, 35 kG
• Three-channel Gaussmeter for determining the magnetic field strength of permanent magnets and systems• Measurement of magnetizing pulses• resolution of 5 3/4 digits• Measuring range: 300 mG, 3 G, 30 G, 300 G, 3 kG, 30 kG, 300 kG• Measuring frequency: DC, 10 Hz - 400 Hz• Measuring accuracy: ± 0,1 % of DC value, ± 2 % of AC value, 0,005 % of measuring range
• Precision laboratory Gaussmeter for determining the magnetic field strength of permanent magnets and systems• Measurement of magnetizing pulses up to 50 kHz• User-friendly measuring instrument• Single-channel Gaussmeter with a resolution of 5 3/4 digits• measuring accuracy of ± 0,05 % of the measured value• Measuring range: 35 mG, 350 mG, 3.5 G, 35 G, 350 G, 3.5 kG, 35 kG, 35 kG• Measuring frequency: DC, 1 Hz - 50 kHz• Measuring accuracy: ± 0,05 % of DC value, ± 1% of AC value, ± 0,005 % of DC measuring range
• Probes for Gaussmeter:• Axial Probes• Transverse Probes• Flexible Transverse Probes
• Magnetic flux• Magnetic flux density• Magnetic field strength• Magnetic moment• Magnetic potential• Polarization• Analogue voltage integrator for measuring all quality-related magnetic parameters• Integrated calibration device
• Helmholtz Coil HC01 150 mm• Helmholtz Coil HC02 210 mm• Measuring coil to determine magnetic moment• Coil constant K= 0,0154cm• Resitance 35 Ohm
• Remanence• Coercive field strength• Maximum energy product• Maximum field strength• Maximum polarization• Hysteresis display• Measurement of all hard magnetic materials(AlNiCo, ferrite, SmCo, NdFeB, plastic composite)• Measurement with constant flux alteration dF/dt
• Remanence• Coercive field strength• Maximum energy product• Specific hysteresis loss• Maximum field strength• Maximum polarization• Effective field strength• Permeability• Specific apparent output• Hysteresis display• Form factor