Politici de confidentialitate
• measurement method ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1• output test voltages 0..50 Vac @ 10A max; 0 – 200 Vac @ 10A max; 0 – 1200 Vac @ 1.5A max (5 min on, 10 min off)• voltage reading range 0..1,250 Vac• current ratio range 0.8..99: ±0.5%, 100..999: ±1.0%, 1,000..5,000: ±2%• phase angle measurement 0..360 degrees• Perform Saturation, Ratio and Polarity Tests• Fully Automated• Comprehensive Graphic and Tabulated Test Reports• Plot Multiple Saturation Curves• Computer Interface & pc software
• Perform Saturation, Ratio and Polarity Tests• Perform CT Winding Resistance Test• Fully Automated• Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments• Plot Multiple Saturation Curves• Store 140 Records (of 10 Saturation Curves)• Computer Interface• USB Flash drive interface
• Performs CT excitation, current-ratio, polarity, and phase angle tests• Measures insulation resistance and winding resistance of the CT seconday windings• Measures the CT's secondary burden• Test record header information including company, substation name, circuit ID, manufacturer, CT serial number, operator name, and test record-comments• Built-in 4.5-inch wide thermal printer• Plot Multiple Saturation Curves• Stores up to 128 CT test plans and 140 test records internally• USB, Bluetooth, and USB Flash drive interface
• Displays turns-ratio from 0.8-15,000• Calculates turns-ratio percentage error• Displays winding polarity and phase angle• Displays excitation current• Battery or AC-powered (ATRT-01B S3 only)• Standalone or computer-controlled
• Highest ratio: 0.8 - 15,000• Built-in 4.5" thermal printer• Excitation current measuring• Phase angle measuring• Computer interface• Name-plate turns ratio calculation• Computed % error based on measured and calculated ratio
• Highest ratio: 0.8 - 15,000• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards• 3 Test voltages available: 8Vac, 40Vac, 100Vac• Phase angle and excitation current measuring• Computer Interface (RS-232C and USB Port)• USB flash drive interface• Name-plate turns ratio calculation• Computed % error based on measured and calculated ratio• Optional 4.5" thermal printer
• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards plus phase shifting transformers• Store up to 128 transformer test-plans in Flash EEPROM• Store up to 112 test records in Flash EEPROM• Built-in USB Flash Drive Interface• Computer Interface (RS-232C and USB Port)• 4.5 Inch thermal printer• Built-in transformer load tap changer
• Standalone or computer-controlled• Can test CVT's rated up to 765 KV• Displays turns-ratios from 75-15,000• Calculates turns-ratio percentage error when nameplate voltages are provided
• Generates its own 3-phase transformer test voltage from single-phase AC or DC Power input• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, • 64 x 128 graphic LCD screen• Store up to 128 transformer test-plans in Flash EEPROM• Store up to 112 test records in Flash EEPROM• Built-in USB Flash Drive Interface• Computer Interface (RS-232C and USB Port)• 4.5 Inch thermal printer• Built-in transformer load tap changer
• Auto discharge circuit for operator safety• 3 resistance reading channels including one dynamic channel• Digital resistance reading from 1 micro-ohm to 500 ohms• Calculate equivalent resistance value at reference temperature• Stores 50 static records and 20 dynamic records• Built-in 4.5-inch thermal printer• Weighs less than 44 lbs.
• Auto discharge circuit for operator safety• 3 resistance reading channels including one dynamic channel• Digital resistance reading from 1 micro-ohm to 500 ohms• 60Vdc power supply , outputting 40 amperes• Calculate equivalent resistance value at reference temperature• Stores 50 static records and 20 dynamic records• Built-in 4.5-inch thermal printer
• accurately measure resistance values from 1 micro-ohm to 2,000 Ohms• Auto-discharge circuit for operator safety• Demagnetizes transformer after test• Selectable test current from 1A to 20A• RS-232C, USB, and Bluetooth computer interfaces• Built-in thermal printer
• accurately measure resistance values from 1 micro-ohm to 500 Ohms• Auto-discharge circuit for operator safety• Demagnetizes transformer after test• Selectable test current from 1A to 40A• RS-232C, USB, and Bluetooth computer interfaces• Built-in thermal printer
• accurately measure resistance from 1 micro-ohm to 2000 Ohms• Perform three phase test on a transformer without the need to switch cables• Can provide individual Delta winding resistance values• Can provide individual Wye (with no neutral) winding resistance values• Demagnetize transformer after test• Selectable test current from 1A to 20A• Computer control via RS-232C, USB, or Bluetooth interface• Built-in 2.5" wide thermal printer
• accurately measure resistance from 1 micro-ohm to 500 Ohms• Perform three phase test on a transformer without the need to switch cables• Can provide individual Delta winding resistance values• Can provide individual Wye (with no neutral) winding resistance values• Demagnetize transformer after test• Selectable test current from 1A to 40A• Computer control via RS-232C, USB, or Bluetooth interface• Built-in 2.5" wide thermal printer
• Range from 1 micro-ohm to 2,000 ohm• Up to 10 Amperes of test current• Auto discharge circuit for operator safety• Built-in 2.5" Thermal Printer, computer interface• Stores 48 records of 63 readings• Weighs less than 27 lbs.